Adder Technology AdderLink IP manual Host configuration, To create a new host entry

Page 52

Host configuration

This page provides the opportunity to configure various details for each of the host systems that may be connected to the AdderLink IP via one or more KVM switch units. There are 32 entries, each of which can be configured with a name, the permitted users, the hot key combinations required to switch to it and, if required, appropriate power control commands.

To get here

1Using VNC viewer or a browser, log on as the ‘admin’ user.

2 Click the ‘Configure’ button in the top right corner. 3 Click the ‘Host configuration’ option.

To create a new host entry

1 Click one of the 32 host entries to reveal a Host configuration dialog.

Name

Enter the name that will be displayed in the viewer window when you click the Host button.

Users

Select the users that will be permitted to connect to this host. Either enter * to allow all users or a list of users separated by commas (e.g. admin,nigel,andy,steve).

Hot keys

Declare the hot key sequence that will cause the KVM switch to link with the required host system. The following notations are used: ‘+‘ means press down a key; ‘-‘ means release a key; * means add a 250 millisecond delay; the entries are not sensitive to case. For instance, to send the command Ctrl + Alt 4 you should enter the following: +CTRL+ALT+4. To send the command Ctrl + Alt 12 you should enter the following: +CTRL+ALT+1-1+2

Note: It is not necessary to specify all keys to be released at the end as all keys are automatically released after the last code. A list of valid codes are given in Appendix 8.

Power On

Enter the code required to make an attached power control unit apply power to the selected host. See Power switching configuration for details.

Power Off

Enter the code required to make an attached power control unit remove power from the selected host. See Power switching configuration for details.

2Enter the required information in each field.

3 Click the OK button.

   



51

Image 52
Contents AdderLink IP Contents Index Four simultaneous remote users Local userModem/ISDN port IP network/InternetAdderView IP features front and rear What’s in the box What you may additionally need    Mounting Single unit rack bracketsDouble unit rack brackets  Host computer or KVM switch ConnectionsLocal keyboard, video monitor and mouse IP network portTo connect a local keyboard, video monitor and mouse To connect the IP network portPower supply connection To connect the power supplyModem/ISDN port To connect a modem or Isdn portPower control port To connect and address the switch boxesInitial configuration Part 1 Local configurationPart 1 Local configuration Part 2 Remote configurationTo perform the initial local configuration Admin passwordTime and Date EncryptionEncryption settings AdderLink IP encryption settingsViewer encryption settings EncryptionWhich restore setting do I use? To restore mouse operation when hot pluggingHot plugging and mouse restoration Recognising an IntelliMouse-style mouseResetting the configuration AdderLink IP asks for an unknown admin passwordTo invoke a configuration reset by switch AdderLink IP does not display the configuration sequencePart 2 Remote configuration To perform the remote configurationNetworking issues Port settingsPositioning AdderLink IP in the network Placing AdderLink IP behind a firewallAddressing To discover a DHCP-allocated IP addressDNS addressing Firewall/router addressEnsuring sufficient security Placing AdderLink IP alongside the firewallPorts Power switching configuration Power control sequencesTo configure the power sequences for each host computer To control two or more ports simultaneouslyPerforming a flash upgrade To perform a flash upgradeConfigure network option Important Wait until the upgrade is completeConnecting to the AdderLink IP Local connectionTo make a local connection To view the local control menuRemote connections To avoid the ‘hall of mirrors’ effectTo connect using the VNC viewer To connect using your Web browserRemote connection by VNC viewer Remote connection by Web browserWhen using the viewer window Using the viewer windowMenu bar Configure Mouse pointersHost selection To select a hostAccess mode shared/private Power controlAuto calibrate Re-synchronise mouseControls Setting the Threshold manually PhaseContrast  Downloading VNC viewer from the AdderLink IP Connecting via dial up modem or Isdn linkIf you need to enter a port number Viewer encryption settings Supported web browsersWindows LinuxTroubleshooting When logging on using VNC viewer, I cannot enter a usernameGetting assistance US +1 888 275Appendix 1 Local configuration menus To access the local configuration menusUnit configuration Network configuration Modem configuration Reset configuration To reset the AdderLink IP configurationWhat is IP access control? Clear IP access controlTo clear IP access control Appendix 2 VNC viewer connection options Colour/EncodingAuto select Preferred encodingInputs MiscDefaults Reload defaultsSave as defaults Save configuration file asAppendix 3 VNC viewer window options Encoding and colour level Appendix 4 Browser viewer optionsSecurity To access the remote configuration menus Appendix 5 Remote configuration menusMain configuration menu Logged on users User accounts Screensaver timeout Hardware VersionFirmware Version Host Keyboard LayoutAdvanced unit configuration Idle timeoutProtocol timeout Force VNC protocolIP network mask IP access controlIP gateway Setting IP access control To define a new IP access control entryTo reorder access control entries To edit/remove access control entriesPower control port Serial port configurationModem port Host configuration To create a new host entryLogging and status To copy and paste the logOccurred Click to clear All log entries Refresh ListIP addresses Appendix 6 Addresses, masks and portsNet masks Net masks the binary explanation Inside a bit-wise and functionBinary equivalent Binary octet afterCalculating the mask for IP access control Single locationsAll locations Address rangesPorts Security issues with portsRouter/firewall address AdderLink IP to power switch cable Appendix 7 Cable and connector specificationsRS232 serial mouse to PS/2 converter cable Appendix 8 Hotkey sequence codes Safety information WarrantyOther products in the Adder range European EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States United States of America Index 

AdderLink IP specifications

Adder Technology's AdderLink IP is a cutting-edge solution designed to extend and manage KVM (Keyboard, Video, Mouse) signals over IP networks. This innovative technology facilitates the remote access and control of computers and servers, making it an essential tool for organizations that require efficient management of their IT resources.

One of the main features of AdderLink IP is its ability to transmit high-resolution video signals with minimal latency. Supporting resolutions up to 4K at 60Hz, it ensures that users experience clarity and responsiveness that is comparable to direct connections. This capability is crucial for industries such as broadcasting, media production, and any environment where graphics-intensive applications are commonplace.

The AdderLink IP employs advanced digitization techniques to ensure high-quality video transmission over standard IP networks. Its use of H.264 video compression allows for efficient bandwidth usage while maintaining image integrity. With this feature, users can easily adapt to various network conditions without compromising performance.

Another standout characteristic is the support for real-time remote access through a web browser, allowing users to connect to their systems from virtually anywhere in the world. Whether for troubleshooting, maintenance, or system management, the AdderLink IP empowers IT professionals with the flexibility they need to perform their duties effectively. The built-in security protocols ensure that access is both secure and reliable.

Moreover, AdderLink IP is designed to be user-friendly. Configuration and management can be performed via an intuitive web interface, simplifying the setup process for users of all technical skill levels. Compatibility with a range of operating systems and devices further enhances its versatility.

Furthermore, the system supports multi-user access, enabling multiple operators to connect to the same devices simultaneously without conflicts. This functionality is particularly useful in collaborative environments where teams need concurrent access to critical systems.

In summary, Adder Technology's AdderLink IP stands out as a robust solution for KVM over IP needs. With its high-quality video transmission, real-time remote access, ease of use, and enhanced security features, it enables organizations to effectively manage their IT infrastructure, thereby boosting productivity and operational efficiency. As the demand for remote access increases, AdderLink IP remains a pivotal component in the evolution of IT management solutions.