Adder Technology AdderLink IP manual Power control port, To connect and address the switch boxes

Page 11
Off = switch upwards On = switch downwards Switch 1 is on the left side

Power control port

The AdderLink IP provides a serial port for connection to one or more optional power control units. This allows you to control the mains power being supplied to the connected host(s) so that an authorised remote user can, if necessary, perform a complete cold reboot on a failed host system.

The control connector of the first power switch is connected, via serial cable, to the rear panel of the AdderLink IP. Any additional power switches are then connected via a ‘daisy-chain’ arrangement to the first power switch. Each power switch box is then given a unique address and access to each power port (8 ports on each power switch box) is gained using a combination of the switch box address and the port number.

‘Daisy-chain’ control

connectionsPower switch

boxes

Box 1

IN

1

2

3

4

5

6

7

8

 

OUT

 

 

 

 

 

 

 

 

Box 2

IN

1

2

3

4

5

6

7

8

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power to computer

 

 

 

 

 

 

 

 

 

Box 2, port 6 - address: 26

Box 3

IN

1

2

3

4

5

6

7

8

 

OUT

 

 

 

 

 

 

 

 

Box 4

IN

1

2

3

4

5

6

7

8

The power ports are connected to the power inputs of each computer and the power switch box(es) are then connected to a mains power supply.

IMPORTANT: Power switching devices have a maximum current rating. It is essential to ensure that the total current drawn by the equipment connected to the power switching device does not exceed the current rating of the power switching device. You must also ensure that the current drawn from any mains socket does not exceed the current rating of the mains socket.

Setting up, configuring and using power switching requires three main steps:

Connect and address the switch boxes ð

Configure the power strings

Operate remote power switching

To connect and address the switch boxes

Note: The AdderLink IP can be powered on during this procedure, however, the switch boxes should be switched off.

1Mount up to four switch boxes in positions where they are close to the computers that they will control and not too distant from the AdderLink IP (preferably within 2.5 metres).

2Use a serial cable with an RJ9 and a 9-pin D-type connector (see Appendix 7 for specification). Connect the RJ9 plug to the socket marked ‘IN’ on the first switch box. Connect the other end to the socket marked ‘COM2’ on the AdderLink IP.

5V

COM2

POWER

CONTROL

 

IN

KVM

CONSOLE

 

3For each of the remaining switch boxes (if used), use a serial cable with RJ9 connectors at both ends (see Appendix 7 for specification). Connect one end to the socket marked ‘OUT’ of the previous box and the other end to the socket marked ‘IN’ of the next box.

4

Set the addressing switches on each switch

Box

Switch 1

Switch 2

 

box using the two micro switches marked

 

1

Off

Off

 

‘Slct’ on the front panel. The box connected

 

directly to the AdderLink IP is Box 1 and so

2

On

Off

 

on, down the daisy-chain line to Box 4 at

3

Off

On

 

the end.

 

4

On

On

5

Connect IEC to IEC power leads between

 

 

 

each port and the power input socket of each computer that requires power switching. Carefully note to which power

ports, on which boxes, each computer is connected. If server systems have multiple power inputs, then each input must be connected via separate ports, which can be on the same, or different boxes.

6 Connect each box to a suitable mains power input.

Now proceed to the configuration stage covered in the Power switching configuration section within the Configuration chapter.

   



10

Image 11
Contents  AdderLink IPContents Index IP network/Internet Four simultaneous remote usersLocal user Modem/ISDN portAdderView IP features front and rear     What’s in the box What you may additionally need  MountingSingle unit rack brackets Double unit rack bracketsConnections Host computer or KVM switchTo connect the IP network port Local keyboard, video monitor and mouseIP network port To connect a local keyboard, video monitor and mouseTo connect a modem or Isdn port Power supply connectionTo connect the power supply Modem/ISDN portTo connect and address the switch boxes Power control portPart 2 Remote configuration Initial configurationPart 1 Local configuration Part 1 Local configurationEncryption To perform the initial local configurationAdmin password Time and DateEncryption Encryption settingsAdderLink IP encryption settings Viewer encryption settingsRecognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationAdderLink IP does not display the configuration sequence Resetting the configurationAdderLink IP asks for an unknown admin password To invoke a configuration reset by switchTo perform the remote configuration Part 2 Remote configurationPlacing AdderLink IP behind a firewall Networking issuesPort settings Positioning AdderLink IP in the networkFirewall/router address AddressingTo discover a DHCP-allocated IP address DNS addressingPorts Placing AdderLink IP alongside the firewallEnsuring sufficient security To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerImportant Wait until the upgrade is complete Performing a flash upgradeTo perform a flash upgrade Configure network optionTo view the local control menu Connecting to the AdderLink IPLocal connection To make a local connectionTo avoid the ‘hall of mirrors’ effect Remote connectionsRemote connection by Web browser To connect using the VNC viewerTo connect using your Web browser Remote connection by VNC viewerMenu bar Using the viewer windowWhen using the viewer window To select a host ConfigureMouse pointers Host selectionRe-synchronise mouse Access mode shared/privatePower control Auto calibrateControls   Setting the Threshold manuallyPhase ContrastIf you need to enter a port number Connecting via dial up modem or Isdn linkDownloading VNC viewer from the AdderLink IP Linux Viewer encryption settingsSupported web browsers WindowsUS +1 888 275 TroubleshootingWhen logging on using VNC viewer, I cannot enter a username Getting assistanceTo access the local configuration menus Appendix 1 Local configuration menusUnit configuration Network configuration Modem configuration To reset the AdderLink IP configuration Reset configurationTo clear IP access control Clear IP access controlWhat is IP access control? Preferred encoding Appendix 2 VNC viewer connection optionsColour/Encoding Auto selectMisc InputsSave configuration file as DefaultsReload defaults Save as defaultsAppendix 3 VNC viewer window options Security Appendix 4 Browser viewer optionsEncoding and colour level Main configuration menu Logged on users Appendix 5 Remote configuration menusTo access the remote configuration menus User accounts Host Keyboard Layout Screensaver timeoutHardware Version Firmware VersionForce VNC protocol Advanced unit configurationIdle timeout Protocol timeoutIP gateway IP access controlIP network mask To edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesModem port Serial port configurationPower control port To create a new host entry Host configurationList Logging and statusTo copy and paste the log Occurred Click to clear All log entries RefreshNet masks Appendix 6 Addresses, masks and portsIP addresses Binary octet after Net masks the binary explanationInside a bit-wise and function Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsRouter/firewall address Security issues with portsPorts RS232 serial mouse to PS/2 converter cable Appendix 7 Cable and connector specificationsAdderLink IP to power switch cable Appendix 8 Hotkey sequence codes Other products in the Adder range WarrantySafety information FCC Compliance Statement United States Radio Frequency EnergyEuropean EMC directive 89/336/EEC United States of America Index 

AdderLink IP specifications

Adder Technology's AdderLink IP is a cutting-edge solution designed to extend and manage KVM (Keyboard, Video, Mouse) signals over IP networks. This innovative technology facilitates the remote access and control of computers and servers, making it an essential tool for organizations that require efficient management of their IT resources.

One of the main features of AdderLink IP is its ability to transmit high-resolution video signals with minimal latency. Supporting resolutions up to 4K at 60Hz, it ensures that users experience clarity and responsiveness that is comparable to direct connections. This capability is crucial for industries such as broadcasting, media production, and any environment where graphics-intensive applications are commonplace.

The AdderLink IP employs advanced digitization techniques to ensure high-quality video transmission over standard IP networks. Its use of H.264 video compression allows for efficient bandwidth usage while maintaining image integrity. With this feature, users can easily adapt to various network conditions without compromising performance.

Another standout characteristic is the support for real-time remote access through a web browser, allowing users to connect to their systems from virtually anywhere in the world. Whether for troubleshooting, maintenance, or system management, the AdderLink IP empowers IT professionals with the flexibility they need to perform their duties effectively. The built-in security protocols ensure that access is both secure and reliable.

Moreover, AdderLink IP is designed to be user-friendly. Configuration and management can be performed via an intuitive web interface, simplifying the setup process for users of all technical skill levels. Compatibility with a range of operating systems and devices further enhances its versatility.

Furthermore, the system supports multi-user access, enabling multiple operators to connect to the same devices simultaneously without conflicts. This functionality is particularly useful in collaborative environments where teams need concurrent access to critical systems.

In summary, Adder Technology's AdderLink IP stands out as a robust solution for KVM over IP needs. With its high-quality video transmission, real-time remote access, ease of use, and enhanced security features, it enables organizations to effectively manage their IT infrastructure, thereby boosting productivity and operational efficiency. As the demand for remote access increases, AdderLink IP remains a pivotal component in the evolution of IT management solutions.