Ethernet Networking for 6K and Gem6K
User Information
Ethernet Networking
Page
Overview
Setup Wizard Available
Example Direct Connect to One Server
Example Direct Connect to PC
Device
Networking Guidelines
Ping
Setting TCP/IP Properties and Static Mapping
Configuring the 6K for Ethernet Communication
Preparing the Controller over RS-232
Changing the 6K’s IP Address or Subnet Mask
Page
Arp -s 192.168.10.30 0-90-55-0-0-1
Connecting the 6K to the PC through Ethernet
Milliseconds
Networking with Other 6K or Gem6K Products Peer-to-Peer
Then the command would be 3NTIP2,172,20,34,170
Communication according to the procedures on
Networking with OPTO22 Snap I/O
Set see ER, TER, Terf
Inputs
Ntio command to specify the type of module in that position
Network Server #
Is set see ER, TER, Terf
Networking with a DVT Vision System
Module # on Server n Range
Networking with an Allen-Bradley SLC 5/05 PLC
Command would be 3NTIP1,172,20,34,124
OPTO22 Ethernet I/O rack
Provided below
5NTCONN1
NTFEN2 Reset
VARB100-VARB103
5NTPOLL50
HAB79
Exchanging data automatically with the PLC. Here is how to
VARB106
PLC
Error messages related to Ethernet networking
Error Conditions
Error Response Possible Cause
Related Error Status register bits are noted below
Network Connect
Ntconn
ER, TER, and Terf
Ntid
Type Syntax Units Range Default Response See Also
Network Sharing Unit ID for Peer-to-Peer Communication
Product
Ntio
Network I/O OPTO22 Configuration
\OUT , \TANI, \TANO, \TIN, \TIO, \TOUT
Ntip
Type Syntax Units Range Default Response
Network IP Address
Server Type
Example
Ntmprb Network Map Binary Variables for Reading from PLC
Network Map Binary Variables for Writing to PLC
Ntmpwb
TNTS, TNTSF, Vari
Ntmpri Network Map Integer Variables for Reading from PLC
Network Map Integer Variables for Writing to PLC
Ntmpwi
VARI35-VARI49
WAITVARI40=22
Network Polling Rate
Ntpoll
Range n =
Network Sharing Rate for Peer-to-Peer Communication
Ntrate
Ntrate *NTRATE50
NTFEN, NTID, SYSPER, VARSHO, Varshi
NTS
Network Program Select Enable
Ntselp
Network Status
Ntwrit
Default Response See Also
Network Write Ascii String to DVT Camera
Tntsf
Tnts
Transfer Network Status
Transfer Network Status full-text report
Varshi
Default n/a
Shared Input Variable for Peer-to-Peer Data Exchange
Varsho
Range i = Default n/a
Shared Output Variable for Peer-to-Peer Data Exchange
Output variable #1 This code is executed on unit #2
Network Analog Input Voltage Status
\ANI
NTIO, \TANI, \TIO, VAR
Network Analog Output
\ANO
\ANO , NTIO, \TANO, \TIO
Network Analog Output Status
\ANO
Network Digital Input Status
\IN
NTIO, \TIN, \TIO, Varb
Network Digital Output
\OUT
\OUT , NTIO, \TIO, \TOUT
Network Digital Output Status
\OUT
VARB9=2\3OUT
Transfer Network Analog Input Status
\TANI
Transfer Network Analog Output Status
\TANO
\TIN
Range n = Default n/a
\TIO
Transfer Network Digital Input Status
Transfer Network Digital Output Status
\TOUT
Digital Outputs
Analog Outputs