3 Technical Specifications

3.1 Power Supply Specifications

Power Supply Type

24VDC

48VDC

HI (110 VDC)

Minimum

Input

18VDC

36VDC

88VDC

Maximum

Fuse Rating

Maximum Power

Input

 

Consumption

36 VDC

5A(F)

 

59 VDC

3.15A(T)

10 W

150 VDC

3.15A(T)

 

 

 

 

NOTES:

1.(T) denotes time-delay fuse

2.For continued protection against risk of fire, replace only with same type and rating of fuse.

3.2Failsafe Relay Specifications

Parameter

Value (Resistive)

 

 

Max Switching Voltage

30VAC, 80VDC

Rated Switching Current

0.3A @ 30VAC

 

1A @ 30VDC, 0.3A @ 80VDC

3.3 Networking Standards Supported

Parameter

10Mbps Ports

100Mbps Ports

Notes

 

 

 

 

IEEE 802.3

￿

 

10BaseT / 10BaseFL

IEEE 802.3u

 

￿

100BaseTX / 100BaseFX

IEEE 802.3x

￿

￿

Full Duplex Operation

 

12

2008 RuggedCom Inc. All rights reserved

Rev101

Image 12
Contents RuggedSwitch RS500  2008 RuggedCom Inc. All rights reserved Rev101 Table of Contents Feature Highlights Product OverviewFunctional Overview Power LED Red RS500 Front Panel DescriptionTx LED Red Rx LED GreenRS500 Top and Bottom View 1 RS500 Top and Bottom ViewInstallation DIN Rail MountingRS500 DIN Rail Mounting & Release Side View  2008 RuggedCom Inc. All rights reserved Rev101 Power Supply DC Input Hipot Dielectric Strength Testing Failsafe Output Wiring and Specifications RS500 Failsafe Relay OutputsTechnical Specifications Power Supply SpecificationsFailsafe Relay Specifications Networking Standards SupportedFiber Optical Specifications Networking Performance SpecificationsType Test Specifications Electrical Safety Levels CommentsTest Ad 16 hrs @ -40C Test Bd 16 hrs @ 85CPhysical Dimensions Operating EnvironmentWarranty Agency ApprovalsParameter Value Comments Agency Standards