3Com 3CR16708-91, 3CR16709-91 manual Viewing IP Information via the Console Port

Page 42

42CHAPTER 3: SETTING UP FOR MANAGEMENT

2Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:

Any of the following baud rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

8 data bits

no parity

1 stop bit

no hardware flow control

Refer to the documentation that accompanies the terminal emulation software for more information.

Set the baud rate on your management device to 19200 baud if you want to view all the system initialization messages.

Viewing IP Information via the Console Port

You are now ready to view the automatically allocated IP information using the command line interface.

1Connect your Switch to the network using an Ethernet cable. As soon as a network connection is made the Switch begins the automatic IP configuration process.

The automatic IP configuration process usually completes within one minute.

2The command line interface login sequence begins as soon as the Switch detects a connection to its console port.

If the login prompt does not begin immediately, press Return a few times until it starts.

3At the login and password prompts, enter admin as your user name and enter your password at the password prompt (or just press Return if you have not yet set a password). If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 11.

Image 42
Contents 3CR16708-91 3CR16709-91 3Com Corporation Campus Drive Marlborough, MA USA United States Government LegendContents Setting UP for Management Problem Solving OutsPage About this Guide Conventions Icon DescriptionConvention Description Related DocumentationDocumentation Comments Pddtechpubscomments@3com.comIntroducing Hardware Features Switch Switch Front View Detail Alert LED Power LED Port Status Leds PoE Status LedsSFP Module Status LED Switch 9 FX only 100BASE-FX Port Status LEDs Switch 9 FX onlyColor Indicates 10BASE-T/100BASE-TX Port Status LEDs LED Alert LEDSwitch Rear View Detail Switch 9 rear viewSwitch Rear View Detail Page Default Settings shows the default settings for the Switch Page Installing the Switch Package Contents Choosing a SuitableSite Air temperature around the Switch does not exceed 50 C 122 F Mounting Wall-mountingUpwards Instructions for Cement WallsInstructions for Wood Walls Make two holes 150 mm 5.9 in. apartPower and Alert LED colors Color StatePower-up Sequence Cross-over Cable Straight-through Cable SFP Operation Installing the Switch Inserting a SFP Transceiver Installing the Switch Setting UP for Management Automatically configured IP information Setting UpConfigure IP information manually for your Switch or view OverviewManual IP Configuration Automatic IP ConfigurationSetting UP for Management Manually Configuring IP Information Pre-requisitesConnecting the Workstation to the Switch Connecting a workstation to the Switch via the console portSetting Up the Switch with IP Information Example top-level command line interface menuConfigured IP ViewingAutomatically Viewing Automatically Configured IP Information Viewing IP Information via the Console Port Methods of Managing a Switch Refer to Setting Up Command Line Interface Management on Refer to Setting Up Web Interface Management onInterface Management Command LineNetwork Using Telnet CLI Management viaSetting Up Web InterfaceChoosing a Browser Over the Network Setting Up SnmpManagement Protocol Snmp can manage a Switch if Management workstationDefault Users User Default Name Password Access LevelDefault Users and Passwords Setting UP for Management Problem Solving Solving Problems Indicated by LEDsProblems Refer to the list of suggested solutions belowSolving Hardware Solving Communication Problems IP AddressingHow do you obtain a registered IP Address? Solving Software Upgrade Problems Problem Solving Safety Information Power Cord Set Japan Important Safety Information This must be approved for the country where it is usedImportant Safety Information ’information de Sécurité Importante Schko’information de Sécurité Importante Wichtige Sicherheitsinformationen Vorsicht EuropeInformación de seguridad importante Schuko Dispositivo Láser DE Clase Importanti Informazioni di Sicurezza CSAAvvertenza porte a fibre ottiche Protezione degli occhi Appendix a Safety Information Adapter Cable RJ-45 Pin Signal DB-9 Pin DirectionRJ-45 to RS-232 Panel. The pinout is shown belowAssignments ConnectorsRJ-45 Pin Pin NumberOfficeConnect Managed Switch 9 and Switch 9 FX Protocols Used for Administration Standards SupportedTerminal Emulation Product ServicesRegister Your PurchaseOnline Access SoftwareTroubleshoot DownloadsContact Us Country Telephone Number Latin America Telephone Technical Support and RepairUS and Canada Telephone Technical Support and Repair Index Snmp Regulatory Notices