TR-127GK/DX
CHAPTER 4
ALIGNMENT
4.0 REQUIRED TEST EQUIPMENT |
|
c DC Power Supply (13.8VDC, 10A) | h Frequency Counter (100 MHz) |
d RF Wattmeter (10W) | i RF Signal Generator (100 MHz) |
e | j Automatic Distortion Meter |
f Automatic Modulation Meter | k Oscilloscope (50 MHz) |
g Audio Signal Generator | • Sinad Meter |
4.1 ALIGNMENT PROCEDURES
This transceiver has been aligned at the factory and does not require any adjustments at installation. The required test equipment listed are used for the test setup or alignment shown in Figure
4.1.1 PLL ALIGNMENT
ITEM
U.U.T. SETTING
ADJUST
POINT
MEASUREMENT
VCO
Set radio to CH 1 AM RX mode. Connect
L23
2.5 VDC ± 0.1
|
|
|
|
| Connect Oscilloscope to TP3. | L24 | Adjust for max. |
|
|
|
|
|
|
|
|
AM Frequency | Set radio to CH 19 AM RX mode. |
|
|
| Connect Frequency Counter to TP3. | L29 | 16.4900MHz ± 20Hz |
|
|
|
|
AM OSC | Set radio to CH 19 AM TX mode. |
|
|
| Connect Frequency Counter to TP5. | L23 | 10.6950MHz ± 10Hz |
- 11 -