Ranger TR-127GK/DX service manual Transmitter Alignment T. Setting Adjust Measurement Point

Page 13

4.1.2 TRANSMITTER ALIGNMENT

ITEM

U.U.T. SETTING

ADJUST

MEASUREMENT

POINT

 

 

 

TX Power

Set radio to CH 19 AM TX mode.

L26, L27,

MAX > 4W

 

Connect RF Power Meter to antenna jack.

L18

Balance Power

 

 

 

Between CH. 1 - 40

AM TX Power

Set radio to CH 19 AM TX mode.

L14

3.8 W

RF Power

 

 

 

Set radio to CH 19 AM TX mode.

 

For a needle reading

Meter

Set S/RF /SWR/CAL Switch to S/RF position.

VR5

of between green and

 

 

 

red area on TX PWR

 

 

 

scale.

AM TX

Set radio to CH 19 AM TX mode.

 

For a needle reading

Modulation

AF signal 30mV, 1 KHz to microphone.

VR4

of 90% on the

 

Set MIC Gain fully clockwise.

 

external modulation

 

 

 

meter.

ANT LED

Set radio to CH 19 AM TX mode.

 

Adjust very slowly

 

Connect 150 ohms load to antenna jack

VR6

until ANT LED just

 

 

 

light on.

4.1.3 RECEIVER ALIGNMENT

 

 

 

 

 

 

ITEM

U.U.T. SETTING

ADJUST

MEASUREMENT

POINT

 

 

 

AM Sensitivity

Set radio to CH 19 AM RX mode.

 

 

 

Set RF GAIN fully clockwise.

L4, L5,L6,L7,

Audio Output > 2V

 

Set SQ fully counter-clockwise.

L8, L9,

S/N > 10 dB.

 

Set VOL Control at 2 o’clock.

L20,L2, L3

 

 

Connect RF SG to antenna jack

VR1

 

 

Frequency 27.185 MHz, 1uV. Mod 30%.

 

 

 

Set radio to CH 40 AM RX mode.

 

 

 

RF SG setting 27.405 MHz.

L4,L5

For Balance Between

 

Set radio to CH 1 AM RX mode.

 

CH 1 and CH 40.

 

RF SG setting 26.965 MHz.

 

 

NB Adjust

Set radio to CH 19 AM RX mode

 

 

 

RF SG setting 27.205 MHz,

L1

Adjust for max.

 

100uV. Mod 30%.

 

 

 

Set switch to NB position.

 

 

 

Connect Oscilloscope to D1 cathode.

 

 

AM Squelch

Set radio to CH 19 AM RX mode.

 

Adjust very slowly

 

Set SQ Control fully clockwise.

VR3

until squelch just

 

RF SG setting 27.185 MHz, 1mV. Mod 30%.

 

closes.

AM S-Meter

Set radio to CH 19 AM RX mode.

 

For a reading of “9”

 

RF SG setting 27.185 MHz, 100uV. Mod 30%.

VR2

on the “S” scale.

- 12 -

Image 13
Contents TR-127GK/DX TR-127GK/DX Table of Contents General TR-127GK/DX Chapter SpecificationsIntroduction TR-127GK/DX OperationControls and Connections Front Panel Page Represents the location of the following connections Rear PanelMHz Frequency Chart Channel Channel FrequencyProcedure to Transmit Operation Procedure to ReceiveMicrophone Your Transceiver Microphone Schematic Alternate Microphones and InstallationPLL Circuit TR-127GK/DX Chapter Circuit DescriptionReceiver Circuit Transmitter Modulation CircuitTR-127GK/DX Block Diagram PLL Alignment T. Setting Adjust Point Measurement Alignment ProceduresTR-127GK/DX Chapter Alignment Required Test EquipmentReceiver Alignment T. Setting Adjust Measurement Point Transmitter Alignment T. Setting Adjust Measurement PointTransmitter test setup TR-127GK/DX Main PCB Adjustment Location Precautions TR-127GK/DX Chapter MaintenanceFuse Replacement Periodic InspectionGeneral TR-127GK/DX Chapter Diagrams Parts ListTR-127GK/DX Rotary Switch PCB EPT092920Z Reference Ranger Part Description Number Part ListTR-127GK/DX Display PCB EPT092930Z Reference Ranger Part Description TR-127GK/DX Main PCB EPT012910A Copper Side Part List TR−127GK/DX Main PCB L23 TR-127GK/DX Schematic Diagram TR-127GK Mechanical Part TR-127DX Mechanical Part AT0127040A  Copyright 2004, Ranger Communications, Inc