Ranger service manual TR-127GK/DX Chapter Specifications, General

Page 3

TR-127GK/DX

CHAPTER 1

SPECIFICATIONS

1.0 GENERAL

Model

TR-127GK, TR-127DX

Channels

40

Frequency Range

26.965 – 27.405 MHz

Emission Modes

AM

Frequency Control

Phase Lock Loop (PLL) synthesizer

Frequency Stability

0.001 %

Operating Temperature Range

-30°C to +50°C

Antenna Impedance

50 Ohms

Input Voltage

13.8V DC

Antenna Connector

Standard SO-239 type

Dimensions

7 1/4”(W) x 9”(D) x 2 1/4”(H)

Weight

3.4 lbs.

1.1 TRANSMITTER

RF Power Output

AM : 4 watts

RF Transmit Modes

AM

Spurious Emissions

- 60dB

Audio Frequency Response

300 to 2500 Hz

Microphone

Dynamic

Output Indicators

Meter shows incoming signal strength, RF output

 

power, and SWR level. Transmit LED glows red

 

when transmitter is in operation.

1.2 RECEIVER

Sensitivity For 10dB S/N

< 1.0∝V

IF Frequency

AM: 10.695 MHz 1st IF, 455 KHz 2nd IF

Image Rejection

- 50dB

Adjacent Channel Selectivity

- 60dB

RF Gain Control

45dB adjustable for optimum signal reception

Automatic Gain Control (AGC) Figure Of Merit

100mV for 10dB Change in Audio Output

Squelch

Adjustable; threshold less than 0.5∝V

Noise Blanker

RF type

Audio Output Power

2.5W @ 10% THD

Audio Frequency Response

300 to 2500 Hz

Built-in Speaker

8 Ohms, 4 Watts

External Speaker (Not Supplied)

8 Ohms, 4 Watts

(SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE)

- 2 -

Image 3
Contents TR-127GK/DX TR-127GK/DX Table of Contents General TR-127GK/DX Chapter SpecificationsTR-127GK/DX Operation IntroductionControls and Connections Front Panel Page Represents the location of the following connections Rear PanelMHz Frequency Chart Channel Channel FrequencyOperation Procedure to Receive Procedure to TransmitMicrophone Your Transceiver Microphone Schematic Alternate Microphones and InstallationTransmitter Modulation Circuit TR-127GK/DX Chapter Circuit DescriptionPLL Circuit Receiver CircuitTR-127GK/DX Block Diagram Required Test Equipment Alignment ProceduresPLL Alignment T. Setting Adjust Point Measurement TR-127GK/DX Chapter AlignmentReceiver Alignment T. Setting Adjust Measurement Point Transmitter Alignment T. Setting Adjust Measurement PointTransmitter test setup TR-127GK/DX Main PCB Adjustment Location Periodic Inspection TR-127GK/DX Chapter MaintenancePrecautions Fuse ReplacementGeneral TR-127GK/DX Chapter Diagrams Parts ListTR-127GK/DX Rotary Switch PCB EPT092920Z Reference Ranger Part Description Number Part ListTR-127GK/DX Display PCB EPT092930Z Reference Ranger Part Description TR-127GK/DX Main PCB EPT012910A Copper Side Part List TR−127GK/DX Main PCB L23 TR-127GK/DX Schematic Diagram TR-127GK Mechanical Part TR-127DX Mechanical Part AT0127040A  Copyright 2004, Ranger Communications, Inc