Reference
Troubleshooting
If there is no sound or if the unit does not operate as you expect, please check the following points first. If this does not resolve the
problem, contact the nearest Roland service center or authorized Roland distributor.
There’s No Sound
•Make sure the Input Level control has not been turned fully counterclockwise.
•Make sure the Input Select switch has been set to the connector where the input signal is connected (Digital Input or Analog Input).
•Make sure the Digital Input select switch has been set to the connector where the input signal is connected (Optical or Coaxial).
•Input a digital signal to the Digital Input connector. No
sound is produced when an analog signal is input.
926
The volume level of the instrument connected to ANALOG INPUT is too low
•Could you be using a connection cable that contains a resistor? Use a connection cable that does not contain a resistor.
During Digital Signal Input, the Stereo Image Is Reversed or Sounds Unnatural, or Output Doesn’t Sound Like Stereo
•Check the setting of the Assign switch (Right, L+R, or Left). The
Specifications
•System
•Enclosure
•Cabinet
1/2" PB (Baffle: 5/8" MDF)
•LF Driver
120 mm (5") Foamed polypropylene cone type, magnetically shielded
•HF Driver
25 mm (1") Soft dome type, magnetically shielded
•Frequency Response
78 Hz to 20 kHz
•Crossover Frequency
2.3 kHz (active third order)
•LF Amplifier Power 20 W
•HF Amplifier Power 10 W
Analog in
•Input Sensitivity
0 dBu (0.775 Vrms)
•Input Impedance
20 k ohms (Balanced/Unbalanced)
Digital in
•Format
Conformity with S/P DIF
•Sample Rate
32 kHz to 96 kHz
•D/A Converter 24 bits
•Controls LEVEL Knob
LF TRIM Knob (80 Hz,
INPUT SELECT SW (Analog In/Digital In) ASSIGN SW (Right/L+R/Left)
DIGITAL INPUT SELECT SW (Optical/Coaxial)
POWER SW
•Indicators
POWER DIGITAL IN
•Connectors
ANALOG INPUT (XLR / 1/4 inch TRS phone type) DIGITAL INPUT (Optical)
DIGITAL INPUT (Coaxial) DIGITAL THRU OUT (Coaxial)