Part 5 Troubleshooting
The marked location isn't where desired.
The center of the base scale may not coincide with Metaza's marking origin point.
To correct displacement between the scale center and the marking origin point, follow the steps below.
Load an unneeded workpiece that will not be used for
1 marking on the base. Prepare a workpiece that is about 10 to 20 mm (1/2 to 1 in.) square.
For information on how to load the workpiece, refer to Part 2, "Loading the Workpiece."
2
3
Grasp the base on both sides and pull back toward you
4 to remove.
When doing this, be careful to ensure that the loaded position of the workpiece does not change.
Measure and make a note of the displacement between
5 the
The figure at right shows a positive displacement of
0.5mm (0.02 in.) for [Width] and a negative displace- ment of 0.5 mm (0.02 in.) for [Length].
Center line
Positive direction for [Length]
Positive direction for [Width]
Center line
0.5 mm | Material |
(0.02 in.) |
|
Go into the [Printers] folder and open the properties
6 for the Metaza driver.
49