To begin setting up your system in a “RING” configuration, perform steps 1 – 13 as outlined in setting up a “BUS” configuration. When doing this, keep in mind that the “OUT” expansion card connector on the first Unit will be connected with an expansion cable to the “IN” expansion card connector on the last Unit to complete the “Ring”.

Jumper JP1 must be removed from the lower expansion cards on two Units in the system to properly maintain cable termination. To identify which Units must have jumper JP1 removed, calculate the total cable length around the “RING”. This is from Unit #1’s “IN” connector, around the “RING” and back to Unit #1’s “OUT” connector.

Jumper JP1 should be removed on Unit #1 and another switch that will divide the “RING” into approximately equal cable length distances. (See Figure 5 for a typical example)

Steps:

(Perform steps 1-13 described in the “BUS” installation first, page 14) (NOTE: Disconnect all cables before removing any expansion card)

1.Remove power from all UltraMatrix switches.

2.Connect an expansion cable from Unit #1’s “OUT” connector (top and bottom expansion cards on the 4xE model) to the last Units “IN” connector (top and bottom expansion cards on the 4xE model) to complete the “Ring”.

3.Remove the bottom expansion card on Unit #1 and the other switch that divide the “RING” into equal distances and remove jumper JP1 (See Figure 2), then replace the expansion cards, cables, and apply power to the two UltraMatrix switches that jumper JP1 was removed. All other UltraMatrix switches should have power off at this time.

4.Make sure a KVM station is connected to UltraMatrix #1, KVM #1.

5.Turn on all KVM stations video monitors and apply power to all UltraMatrix switches. (Wait for the internal diagnostic check to complete and fade out).

6.Switch the KVM station to CPU port #1 on Unit #1 by pressing and releasing the left control [Ctrl] key, type in “1” and press [Enter].

7.Pre-configure the CPU port, if needed, as outlined in steps 4a-f on page 12 if the computer being connected does not use a PC2 type keyboard or PS/2 mouse (defaults). Pre-configure the CPU port before connecting the computer. If the computer uses a PC2 type keyboard and PS/2 mouse, connect it to the corresponding CPU port. No pre-configuration is needed.

8.Boot the computer if power is not applied. You should see the boot up sequence on the KVM monitor. If the computer was connected to a pre-configured CPU port with power applied, you should see that computers video.

20ULTRAMATRIX E-SERIES MANUAL

Image 26
Contents Installation and Operations Manual Limited Warranty FCC/IC STATEMENTS, EU Declaration of Conformity Table of Contents Tables AppendicesPage About this manual IntroductionDisclaimer IntroductionFeatures Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Models Overview System OverviewUltramatrix E-SERIES Manual Two expansion cards are Ultramatrix E-SERIES Manual Site planning Installation Switch Installation Single UnitUltramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Switch Installation Multiple units BUS topology Connecting the expansion units Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Switch Installation Multiple units Ring topology Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Switch Installation Multiple units Split-BUS topology Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Configuration Menus Menu structureKVM Configure System menu Configure system System settings Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual PC2 Ultramatrix E-SERIES Manual BUS Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Configure Profile menu Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Configure Group Computer KVM CPU CPU YES User operating instructions Keyboard commandsOperation Login Control Room Computer select menu Status Mail server Serial Port Serial port usage RS232Serial menu Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Switching using the serial port Serial Device Support Serial device supportComputer Serial 9600,N,8,1 Maintenance and Repair ServiceService Information Technical SupportSafety SafetySafety and EMC Regulatory Statements Ultramatrix E-SERIES Manual Troubleshooting TroubleshootingUltramatrix E-SERIES Manual Appendices CPU/KVM DB25F ACC-CIRX/45 CPU Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual MX21C Ultramatrix E-SERIES Manual Message Description Ultramatrix E-SERIES Manual Ultramatrix E-SERIES Manual Page Page Stancliff Road Phone 281 Houston, Texas