Configuration Menu Items

In the examples below, <ENTER> means "press the ENTER key", not "type the characters <ENTER>. Output from the Caretaker Plus is shown in courier type. Input from the user is shown in underlined courier type.

Protocol

The protocol consists of the baud rate, parity, word length, number of stop bits, and flow control. The factory default is 9600 baud, no parity, 8 bits, 1 stop, and DTR flow control. You may configure the protocol separately for each port. The port is changed to the new protocol, but the change is not saved in non-volatile memory until the Keep command is issued. To change the protocol enter P to the choice prompt. You will be asked which port you want to change. Enter the port number or R to change a range of ports. The range option will set any changed item(s) (i.e. baud rate, parity, etc.) to the new common value(s) for all the ports selected; however, any unchanged item(s) will remain at the previous setting(s). If you enter 'R', you will be asked for the range of ports you want to change. The ending port number must be greater than or equal to the starting port number. Note that if you hit just a return to the ending port number, that port number will be the same as the starting port number and only one port will be changed. After entering the port(s) to be changed, answer the subsequent prompts. Note that protocol changes are made when you exit the configuration menu.

Single Port

Enter choice (P.T,F,I,D,A,K.X, or H for help) <ENTER> Enter the port number (0-8 or R) 3<ENTER>

Enter baud rate (19200, 9600, 7200, 4800, 3600, 2400. 1800, 1200, 600, 300, 150, 134.5, 110, 75, 50) 1200<ENTER>

Enter parity type (N=None, E=Even, O=Odd, M=mark, S=Space) E<ENTER> Enter word length (5, 6, 7, 8) 7<ENTER>

Enter stop bits (1,2) 1<ENTER>

Enter flow control (D=DTR X=XONIXOFF) X<ENTER>

Range of Ports

Enter choice (P.T,F,I.D,A.K,X, or H for help) P<ENTER> Enter the port number (0-8 or R) R<ENTER>

Enter the starting port number (0-8) 3<ENTER> Enter the ending port number (0-8) 4<ENTER>

Enter baud rate (19200, 9600, 7200. 4800, 3600. 2400, 1800, 1200, 600, 300, 150, 134.5. 110, 75, 50) 2400<ENTER>

Enter parity type (N=None, E=Even, O=Odd, M=mark. S=Space) (ENTER> Enter word length (5, 6, 7, 8) <ENTER>

Enter stop bits (1, 2) <ENTER>

Enter flow control (D=DTR X=XON/XOFF) D<ENTER>

Timeout

The timeout is used to automatically disconnect a port that is inactive (not sending or receiving data) from the shared device. The timeout specifies the length of time a port must remain inactive before the Caretaker Plus disconnects it from the shared device and connects the next port in the queue. The factory default is 20 seconds, but may be changed to be from 2 to 255 seconds. To change the timeout, enter T to the choice prompt and enter the new timeout value.

Enter choice (P,T,F,I,D.A,K,X, or H for help) T<ENTER>

Enter timeout (2-255) IO<ENTER>

CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL

9

Image 13
Contents Stancliff Road Houston, Texas Phone 281 Installation Operations ManualPage Limited Warranty Table of Contents Disclaimer FeaturesIntroduction First Steps Model Number and OptionsCaretaker Plus Front Panel Display Front Panel DisplaySerial Set-Up for PCs Mode LPT1+COM1Serial Set-up For Other Computers or Terminals Caretaker Plus Rear Panel Serial Model Parallel Set-Up Mode LPT1,,P Caretaker Plus Rear Panel Parallel Model Cabling ConfigurationParallel Cabling Serial CablingDisabled EnabledElectronics None DTRCaretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Front Switches TimeoutADV. Features ProtocolCaretaker Plus Installation and Operations Manual Configuration Commands =DTR/DSR Protocol CommandCaretaker Plus Installation and Operations Manual Operations Explanation Printer Initialization Signal Parallel Models OnlyCopy CON COM1CR TimeoutInitialization String W W Caretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Troubleshooting TroubleshootingError Maintenance and Repair Diagnostics Parallel Units Serial UnitsNone Diagnostics Loopback Test Connectors Appendix a Serial Cabling AppendicesSerial Computers Serial PrintersAppendix B Pinout Specifications Appendix C MP1000 Memory Board InstallationAdding Chips to an Empty Board or Adding Additional Chips Appendix E General Specifications Appendix D Factory DefaultsPage Stancliff Road Phone 281 Houston, Texas