Rose electronic Automatic Switch manual Diagnostics

Page 30

DIAGNOSTICS

Diagnostic Modes

The Caretaker Plus has an extensive self-test diagnostic capability. Normally these features are only accessed by a technician to determine a failure with the unit. Through the diagnostic modes, you can:

Print the configuration menu

Print a repeating test pattern on the printer

Restore the non-volatile memory to its factory defaults Test the EPROM, buffer memory, and non-volatile memory Test all signals on each I/O port

There are three diagnostic modes that can be entered.

1.Short test - Print configuration menu, printer test pattern, and reset non-volatile memory to factory default are accessed through this mode. This test is called the short test because its test of the dynamic memory (test #2) is not as long as the other tests.

2.Long test with loopback connectors - tests all functions of the unit except the I/O ports are only tested for open loop conditions.

3.Long test with no loopback connectors - tests all functions of the unit including that the I/O port drivers and receivers are all functional.

Short Test

This mode is entered by holding down both front panel switches while turning the unit's power on. The unit will continuously go through its power up sequence and stop if it encounters an error, displaying the error on the LEDs and indicating servicing is required. Note that the memory test (test t2) performed in this mode is more extensive and thus takes more time to execute than in the power up test. It is not as extensive as the long tests. To leave this mode power down the unit, then power back up with no switches pressed.

Restore To Factory Default

There are two ways to reload the factory default configuration. The first is if an error occurs in powering up the unit and the unit halts with error 4 (ERROR LED and LED 4 are lit). To reload the defaults push the advance switch, the unit is then ready for operation. if this occurs frequently, it indicates excessive static electricity or poor power to the unit.

The other method of reloading the factory defaults is through the short test diagnostic mode. This mode is entered by powering the unit off and pressing both the advance and select switch and then powering up the unit. Release the advance switch (the one on the left) and continue to hold the select switch (the one on the right) while the switch cycles through its normal power up sequence. The switch will halt with LED 4 lit. Release the select switch. Momentarily press the advance switch and all lights should come on to indicate a successful reload of the factory defaults. The unit stays in this short diagnostic mode and continuously cycles through the 4 tests. On a subsequent cycle, It you receive an error 4 (restore to default failure), the unit must be serviced. To resume normal operation, you must power the unit off and back on. The unit is now set at its factory defaults. You must reconfigure the unit, if necessary, to correspond to your equipment settings.

26

CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL

Image 30
Contents Installation Operations Manual Stancliff Road Houston, Texas Phone 281Page Limited Warranty Table of Contents Features DisclaimerIntroduction Model Number and Options First StepsFront Panel Display Caretaker Plus Front Panel DisplayMode LPT1+COM1 Serial Set-Up for PCsSerial Set-up For Other Computers or Terminals Caretaker Plus Rear Panel Serial Model Mode LPT1,,P Parallel Set-UpCaretaker Plus Rear Panel Parallel Model Parallel Cabling ConfigurationCabling Serial CablingElectronics EnabledDisabled None DTRCaretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual ADV. Features TimeoutFront Switches ProtocolCaretaker Plus Installation and Operations Manual Configuration Commands Protocol Command =DTR/DSRCaretaker Plus Installation and Operations Manual Operations Printer Initialization Signal Parallel Models Only ExplanationTimeout Copy CON COM1CRInitialization String W W Caretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Troubleshooting TroubleshootingError Maintenance and Repair Diagnostics Serial Units Parallel UnitsNone Diagnostics Loopback Test Connectors Serial Computers AppendicesAppendix a Serial Cabling Serial PrintersAppendix B Pinout Specifications Installation Appendix C MP1000 Memory BoardAdding Chips to an Empty Board or Adding Additional Chips Appendix D Factory Defaults Appendix E General SpecificationsPage Stancliff Road Phone 281 Houston, Texas