Parallel Enable Logic Command

This command allows the Caretaker Plus to recognize when a computer that is connected to a parallel port on the Caretaker Plus is turned off so that the Caretaker Plus will not accept data from the PC. The factory default is to enable parallel enable logic. When this feature is enabled, the Caretaker Plus requires the INIT line to be high and the SELECT line to be low before receiving any data from the port. If a character other than Y or N is used no action is taken.

Initialization String Command

This command is used to change the initialization string. Enabling of the initialization string occurs when a valid string is entered. Disabling of the string is done by entering a string with the first character set to ASCII 00 (NULL). To enter the characters of the string, you type the ASCII number of each character in hexadecimal followed by an H without commas or spaces in between. Note that NULL serves as a terminator to the initialization string, so it will not be printed along with the string, and any characters following a NULL will be ignored.

Command syntax is: !@issssssss

where ssssssss is the new init string. To disable the string the first char must be 00. Examples:

To enter the string <ESC>E .. . . · · · · · · · !@llBH45H<ENTER> To disable the string .... · · · · · · · · · · · . . . !@I<ENTER>

CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL

15

Image 19
Contents Stancliff Road Houston, Texas Phone 281 Installation Operations ManualPage Limited Warranty Table of Contents Disclaimer FeaturesIntroduction First Steps Model Number and OptionsCaretaker Plus Front Panel Display Front Panel DisplaySerial Set-Up for PCs Mode LPT1+COM1Serial Set-up For Other Computers or Terminals Caretaker Plus Rear Panel Serial Model Parallel Set-Up Mode LPT1,,PCaretaker Plus Rear Panel Parallel Model Serial Cabling ConfigurationCabling Parallel CablingNone DTR EnabledDisabled ElectronicsCaretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Protocol TimeoutFront Switches ADV. FeaturesCaretaker Plus Installation and Operations Manual Configuration Commands =DTR/DSR Protocol CommandCaretaker Plus Installation and Operations Manual Operations Explanation Printer Initialization Signal Parallel Models OnlyCopy CON COM1CR TimeoutInitialization String W W Caretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Troubleshooting TroubleshootingError Maintenance and Repair Diagnostics Parallel Units Serial UnitsNone Diagnostics Loopback Test Connectors Serial Printers AppendicesAppendix a Serial Cabling Serial ComputersAppendix B Pinout Specifications Appendix C MP1000 Memory Board InstallationAdding Chips to an Empty Board or Adding Additional Chips Appendix E General Specifications Appendix D Factory DefaultsPage Stancliff Road Phone 281 Houston, Texas