Rose electronic Automatic Switch manual Timeout, Copy CON COM1CR

Page 22

Timeout

The default setting of 20 seconds is sufficient for most applications. Some computers, however, start printing and then pause to do some type of calculation or processing and then resume printing. If this pause is greater than the timeout setting of the switch. then another computer could start printing and possibly interrupt the printing of the first job and ruin its printout. In this case, it is necessary to increase the value of the timeout through the configuration process. Please refer to the timeout in the section on CONFIGURATION for more information.

NOTE: In the following examples (CR) means hit the enter key,

(F6) means hit the F6 key (this will echo on the computer as hZ) The example is given for COM1 of the PC connected to a serial unit. Substitute with COM2 if your serial port is COM2 or LPTI or LPT2 if you have a parallel unit.

To set the timeout to 60 seconds from a PC, do the following steps:

1.Momentarily hold in the advance and select switches until the mode and busy lights light up.

2.From the computer connected to port 1 on the unit type in the following:

COPY CON COM1(CR)

When typed at the DOS prompt. you get a blank line

!@T060!@(F6)(CR)

Enter the timeout command and keep command

1 file(s) copied

This message displays and you return to DOS

3.Momentarily hold in the advance and select switches until the mode and busy lights turn off.

18

CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL

Image 22
Contents Installation Operations Manual Stancliff Road Houston, Texas Phone 281Page Limited Warranty Table of Contents Disclaimer FeaturesIntroduction Model Number and Options First StepsFront Panel Display Caretaker Plus Front Panel DisplaySerial Set-Up for PCs Mode LPT1+COM1Serial Set-up For Other Computers or Terminals Caretaker Plus Rear Panel Serial Model Parallel Set-Up Mode LPT1,,PCaretaker Plus Rear Panel Parallel Model Parallel Cabling ConfigurationCabling Serial CablingElectronics EnabledDisabled None DTRCaretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual ADV. Features TimeoutFront Switches ProtocolCaretaker Plus Installation and Operations Manual Configuration Commands Protocol Command =DTR/DSR Caretaker Plus Installation and Operations Manual Operations Printer Initialization Signal Parallel Models Only ExplanationTimeout Copy CON COM1CRInitialization String W W Caretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Troubleshooting TroubleshootingError Maintenance and Repair Diagnostics Parallel Units Serial UnitsNone Diagnostics Loopback Test Connectors Serial Computers AppendicesAppendix a Serial Cabling Serial PrintersAppendix B Pinout Specifications Installation Appendix C MP1000 Memory BoardAdding Chips to an Empty Board or Adding Additional Chips Appendix D Factory Defaults Appendix E General SpecificationsPage Stancliff Road Phone 281 Houston, Texas