Rose electronic Automatic Switch manual Configuration, Parallel Cabling, Serial Cabling

Page 11

CABLING

One of the most important steps in installing the Caretaker Plus is to connect the correct cables. We have tried to give as much information as possible to specify the correct cable. Please refer to Appendix A and B. Also refer to the previous section.

Parallel Cabling

Parallel units with Centronics connectors use standard IBM parallel cables to connect from PCs to the switch (port 1-8). A straight through cable with male Centronics connectors on each end is used to connect from the switch (port 0) to the printer.

Parallel units with female DB25 connectors use a straight through cable with male DB25 connectors on each end to connect from PCs to the switch (ports 1-8). A standard IBM parallel printer cable is used to connect from the switch (port 0) to the printer.

Parallel cabling in excess of 25 feet in length should be routed with caution. The maximum distance that a cable may be run is dependent upon the construction of the cable and its routing. For extended distances, shielded cable or ribbon cable should be used. Routing near machines that may create electrical noise, such as elevator motors, fluorescent lights, or air conditioning compressors should be avoided. Typically a cable run for 100 feet will work reliably but is not guaranteed. Low capacitance cable should be specified for long lengths of cable. Rose Electronics can construct the proper cabling to your specified length.

Serial Cabling

Proper serial cabling and pinout is crucial in the installation of your serial port peripheral. Appendix A gives a comprehensive list of the cable pinouts required for a successful installation.

Serial cabling in excess of 100 feet should be routed with caution. The maximum cable length depends upon the construction of the cable and its routing. For extended runs, shielded cable should be used. Avoid routing near fluorescent lights, air conditioning compressors, or machines that may create electrical noise. Cable length and baud rate are inversely proportional: the longer the cable, the slower the baud rate must be. The RS-232-C specification recommends a maximum cable length of 50 feet at 9600 baud, however, with low capacitance cables, runs of greater distance are often successful. Rose Electronics can construct the proper cabling to your specified length.

CONFIGURATION

Configuration is unnecessary if the factory default settings are acceptable (see APPENDIX D for the FACTORY DEFAULT SETTINGS. The most common items to be configured are the timeout, initialization string, form feed, and for serial units the protocol.

There are two methods to configure the unit --by menu and by command. The configuration menu can only be accessed through a serial port. Parallel units are required to be configured by command. Serial units can be configured by command, but it is usually more convenient to use the configuration menu.

To access the configuration menu, a dumb terminal or a PC emulating a dumb terminal must be connected to port 1. The PC or terminal must be set to 9600 baud, 8 bits, no- parity, 1 stop bit. After connecting your terminal or PC, power up the Caretaker Plus and wait for the power up tests to complete. When no LEDs on the front panel are lit, press both front panel switches at the same time. The MODE and BUSY LEDs will illuminate

CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL

7

Image 11
Contents Stancliff Road Houston, Texas Phone 281 Installation Operations ManualPage Limited Warranty Table of Contents Introduction FeaturesDisclaimer First Steps Model Number and OptionsCaretaker Plus Front Panel Display Front Panel DisplaySerial Set-up For Other Computers or Terminals Mode LPT1+COM1Serial Set-Up for PCs Caretaker Plus Rear Panel Serial Model Caretaker Plus Rear Panel Parallel Model Mode LPT1,,PParallel Set-Up Serial Cabling ConfigurationCabling Parallel CablingNone DTR EnabledDisabled ElectronicsCaretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Protocol TimeoutFront Switches ADV. FeaturesCaretaker Plus Installation and Operations Manual Configuration Commands =DTR/DSR Protocol CommandCaretaker Plus Installation and Operations Manual Operations Explanation Printer Initialization Signal Parallel Models OnlyCopy CON COM1CR TimeoutInitialization String W W Caretaker Plus Installation and Operations Manual Caretaker Plus Installation and Operations Manual Troubleshooting TroubleshootingError Maintenance and Repair Diagnostics None Serial UnitsParallel Units Diagnostics Loopback Test Connectors Serial Printers AppendicesAppendix a Serial Cabling Serial ComputersAppendix B Pinout Specifications Appendix C MP1000 Memory Board InstallationAdding Chips to an Empty Board or Adding Additional Chips Appendix E General Specifications Appendix D Factory DefaultsPage Stancliff Road Phone 281 Houston, Texas