Panduit PTR3E HEX Dump Mode, Initializing ROM Online QTY000000, Potentiometer Adjustments, Pitch

Page 43

4.If the printer did not beep and print a status label, turn the printer off and check your data stream for errors and start the download process over.

5.If the custom codes are correct, press the FEED key to accept them and terminate the download process. If they are incorrect, turn the printer off without pressing the FEED key and begin the process again.

HEX DUMP MODE

In addition to the User Test Print Labels, the printer can print the contents of the receive buffer in a hexadecimal format to allow the data stream to be examined for errors and troubleshooting.

INITIALIZING ROM V00.00.00.00

ONLINE QTY:000000

The Hex Dump Mode is entered by placing DSW2-4 in the ON position and powering the printer on.

1.The printer is now ready to receive data.

2.Send the data stream to the printer.

3.The received data will be printed in a hexadecimal format

4.To return the printer to normal operation, place DSW2-4 in the OFF position and power the printer off and then back on.

POTENTIOMETER ADJUSTMENTS

PITCH

After the pitch has been set with the LCD Control Panel, it is sometimes desirable to make minor adjustments. This can be done using the PITCH potentiometer on the front panel. This potentiometer is set at the factory so that it has a range of +/-3.75

mm.The midpoint setting should have no effect on the pitch. Turning the potentiometer all the way clockwise should move the print position 3.75 mm up towards the top edge of the label. Turning it all the way counter clockwise should move the print position down 3.75 mm.

1.While depressing the FEED key on the front panel, power the printer on.

2.When you hear one beep from the printer, release the FEED key and the printer will display on the LCD panel a message asking what type of Test Label you want to print.

3.Use the LINE key to step to the Configuration selection and press the FEED key to accept the selection.

4.Use the LINE key to select the Test Label size. After the size is selected, press the FEED key to accept the selection and the printer will begin to print test labels continuously.

5.Adjust the PITCH potentiometer on the front panel until the first print position is at the desired location on the label. If the potentiometer does not35

Image 43
Contents Operator and Technical Reference Manual Panduit PTR3E Safety Practices Information to User Warranty Information PTR3E Operator Manual Table of Contents IEEE1284 Parallel Interface RS232C Serial Interface Page Introduction Section Printer OverviewSpecification PTR3E General Printer SpecificationsPotentiometer Adjustments Matrix Fonts Character FontsMSI Postnet UCC/EAN-128 BAR CodesPhysical Power RequirementsSection Installation Here,butarethe OperatorManual ExtraRibbonCore Door Follow these steps to properly load labels into PTR3EPage Sensor Loading THERibbonSpindleRIBBONRewind Page Label Use Page Page Label Sensor Adjustment Printer Set Up DIP Switch PanelsOFFON123DSW245678 Mode Selection Print Speed Adjustment DSW2-8 . SeeRepeat Print via Ex er ExternalProtocol Selecti Default S Tti gsPrinter Adjustments Online QTY000000 Offline InitializingPrint Speed ± 00mm Pitch OffsetInitializing ROM Advanced Mode Zero Slash YES no Auto Online Ignore CR/LF YES no Print OffsetGAP Input Character Pitch Prop Fixed Advanced ModeService Mode Advanced Mode Service ModeEuro Code Select Language English Auto Online Feed YES no Feed on Error Reprint W/FEEDFORWARD/BACKFEED Distance Default FORWARD/BACKFEED Distance XXXmmPriority Setting Command LCD Service Mode Test Print ModeInitializing ROM Default Setting ModeDefault Setting YES no Default Setting CompletedPitch HEX Dump ModePotentiometer Adjustments Initializing ROM Online QTY000000Display Backfeed OffsetPrint Counter Clear None Factory ModeMaintenance Mode DIPSW2-4 ON-OFF Display Counter ValuesPage Adjusting the Print Quality ProceduresDarkness Print Print,thedarkness Cleaning the Print Head and Platen Cleaning the Print HEAD, Platen and RollersCleaning the Rollers and Guides Cleaning the SensorsReplacing the Print Head Open the Top and Side Access doorsThed,centeritwill Supplies needed Replacing the FuseCleaning and Maintenance Interface Types Electrical SpecificationsIEEE1284 Parallel Interface RS232C Serial Interface General SpecificationsUsing the IEEE1284 Parallel Interface Initial ChecklistTroubleshooting Using the RS232C Serial InterfaceLED LCD Audible Error Condition To Clear Message Beep Error Signals

PTR3E specifications

The Panduit PTR3E is a key player in the realm of cable management and network infrastructure solutions, designed to meet the evolving demands of modern telecommunications and data center environments. This innovative product is part of Panduit's extensive lineup, which is known for robustness, efficiency, and versatility.

One of the standout features of the PTR3E is its exceptional modular design. This modularity allows for straightforward installation and easy reconfiguration as network demands change. The PTR3E supports a wide array of mounting options, making it suitable for various installations, from wall-mounted system configurations to versatile rack setups. This flexibility ensures that it can fit seamlessly into existing infrastructures while providing the capability to scale efficiently.

Another significant characteristic of the PTR3E is its use of advanced materials. Constructed from high-quality, durable plastics, it offers excellent resistance to environmental factors including temperature variations and humidity, which are common challenges in data centers and network closets. This resilience not only increases the lifespan of the product but also minimizes maintenance costs and downtime.

In terms of technology, the PTR3E is engineered to support high-density fiber and copper cabling solutions. It can accommodate a variety of cable types, ensuring compatibility with different systems and reducing the clutter that often hampers network efficiency. The intelligent design features integrated strain relief and cable management capabilities that help in organizing cables without imposing undue stress on connectors and ports.

Moreover, the PTR3E is designed with user operation in mind. Its intuitive design facilitates easy access to cables and ports, allowing for quicker troubleshooting and upgrades. This accessibility is critical in fast-paced environments where time is of the essence, making it a preferred choice for IT professionals.

Furthermore, the PTR3E adheres to the latest industry standards, ensuring compliance with regulatory requirements. This reliability is crucial for organizations that prioritize system integrity and performance. With the integration of Panduit's technology, the PTR3E not only enhances operational efficiency but also aligns with sustainability goals, reducing environmental impact in systems design.

In conclusion, the Panduit PTR3E is a versatile, durable, and technologically advanced solution for cable management in today’s fast-paced networking environments. Its modularity, high-quality materials, and thoughtful design make it an essential component for any organization looking to optimize its network infrastructure.