Symptom
AC indicator lit orange
Midspan repeatedly shutsdown for few minutes and then starts
The end device operates, but there is no data link.
Midspan port indicator is blinking at a 1 sec. rate
Midspan port indicator is blinking at a 0.5 sec. rate
PD-6548
Table 3-1: Troubleshooting Steps
Corrective Steps
Verify that the ventilation holes are not blocked.
1.Verify that the port indicator on the front panel is continuously lit.
2.If an external power splitter is in use, replace it with a
3.Verify that for this link, you are using standard UTP/FTP Category 5 straight
4.Try to
This is a safe condition. The blinking green indication is due to:
1.A device, not compliant to IEEE 802.3af, was detected.
2.Terminals 4/5 and 7/8 are shorted together.
3.Forced external power fed into the port.
During these conditions, port power is disconnected.
This is a safe condition. The blinking green indication is due to a power management event.
In such event the corresponding port to the indicator, requires power that exceeds power budget capability of the Midspan. During these conditions, port power is disconnected.
A port will operate when total power consumption of the Midspan decreases.
try to connect the PD to another Midspan to verify that the PD is valid.