PD-6548
1.2Power Cord
In the event that the power cord is replaced, the replacement must meet local requirements.
•For reliable connection to an AC MAINS SUPPLY, equipment provides an appliance IEC60320 inlet for connection of a detachable power supply cord.
•The power socket outlet must be located near the Midspan and be easily accessible. The only way to remove power from the unit is by disconnecting the power cord from the outlet
•This unit operates under SELV (Safety Extra Low Voltage) conditions according to EN60950/IEC 950. The conditions are only maintained if the equipment to which it is connected, also operates under SELV conditions.
U.S.A. and Canada
Denmark
Switzerland
France and
Peru
U.K
The cord must be
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
The cord set must have a rated current capacity of at least 10 A.
The attachment plug must be an
The supply plug must comply with section
The supply plug must comply with SEV/ASE 1011.
This unit cannot be powered from IT supplies. If your supplies are of the IT type, this unit must be powered by 230 V (2P+T), via an isolation transformer with a 1:1 ratio and with the secondary connection point labeled Neutral, connected directly to ground
The Power over Ethernet Midspan is covered by General Approval, NS/G/12345/J/100003, for indirect connection to a public telecommunications system