3.8Troubleshooting

3.8.1Preliminary Steps

If you encounter problems, verify that:

1.Power is applied to the Midspan

2.A crossover-type Ethernet cable has not been used

3.The Ethernet cable from the network is connected to the Data input port

4.The Ethernet cable to the PD is connected to the Data & Power output port

3.8.2Troubleshooting Guide

This paragraph provides a symptom and resolution sequence in order to assist in the troubleshooting of minor operating problems. If the steps given do not solve your problem, do not hesitate to call your local dealer for further assistance. Refer to Table 3-1.

Table 3-1: Troubleshooting Steps

Symptom

Midspan does not power up

A port indicator is not lit and the corresponding PD does not operate.

Corrective Steps

1.Verify that a known-good power cord is used.

2.Verify that the voltage at the power inlet is between 100 and 240 Vac.

3.Remove and re-apply power to the device and check the indicators during power up sequence as described in Para. 3.7.

1.The Midspan did not detect a PD and therefore the port is not enabled.

2.Verify that the PD is designed for Power over Ethernet operation.

3.Verify that you are using a standard Category 5/5e/6, straight-wired cable, with four pairs.

4.If an external power splitter is in use, replace it with a known-good splitter.

5.Verify that the PD is connected to the Data & Power output port.

6.Try to reconnect the same PD to a different port on the same or into another Midspan. If it works, there is probably a faulty output port or RJ-45 connection.

7.Verify that port shutdown command was not issued via the Web manaegment.

Power over Ethernet Solutions

23

Cat. No.: 06-6860-056

Image 23
Contents User Guide Power over Ethernet MidspansPD-6548 Power over Ethernet Solutions PD-6548 DisclaimerContents List of Tables List of FiguresElectrical Compatibility Approvals Verifying Kit ContentsSafety Standard Approvals PD-6548 Model Numbers DefinitionAbbreviations General Guidelines Safety InformationA. and Canada Denmark Switzerland France Peru Power CordPower Management About the Power over Ethernet Midspan10/100BASE-TX Ports Definition Power over Ethernet Midspan, Front ViewPrimary Power Indicators IndicatorsPort Status Indications Power Status IndicationsConsole Ethernet Connector ConnectorsRear Panel RJ45 Input Plug Per Channel PD-6548 Console Cable D-type ConnectorDescription PD-6548 Front Panel RJ45 Output Plug per channel Connecting to the Midspan Power over Ethernet SolutionsBackground Installing the Power over Ethernet MidspanRack Mounting Brackets Chasis ‘Ears’ Routing the Input Ports CablesCable Connections Assembling Midspan to Rack Powering up Connecting Data CablesConnecting Power Cables Troubleshooting Steps TroubleshootingPD-6548 Troubleshooting Steps Physical Specifications Technical SpecificationsManagement Deployment Remote Web ManagementPD-6548 Power over Ethernet Solutions Part Number Rev