3.8Troubleshooting
3.8.1Preliminary Steps
If you encounter problems, verify that:
1.Power is applied to the Midspan
2.A
3.The Ethernet cable from the network is connected to the Data input port
4.The Ethernet cable to the PD is connected to the Data & Power output port
3.8.2Troubleshooting Guide
This paragraph provides a symptom and resolution sequence in order to assist in the troubleshooting of minor operating problems. If the steps given do not solve your problem, do not hesitate to call your local dealer for further assistance. Refer to Table
Table 3-1: Troubleshooting Steps
Symptom
Midspan does not power up
A port indicator is not lit and the corresponding PD does not operate.
Corrective Steps
1.Verify that a
2.Verify that the voltage at the power inlet is between 100 and 240 Vac.
3.Remove and
1.The Midspan did not detect a PD and therefore the port is not enabled.
2.Verify that the PD is designed for Power over Ethernet operation.
3.Verify that you are using a standard Category 5/5e/6,
4.If an external power splitter is in use, replace it with a
5.Verify that the PD is connected to the Data & Power output port.
6.Try to reconnect the same PD to a different port on the same or into another Midspan. If it works, there is probably a faulty output port or
7.Verify that port shutdown command was not issued via the Web manaegment.