Quantum 890 USE 155 manual Introducing the Modbus to Ethernet Bridge, Bridge Applications

Page 10

Modbus to Ethernet Bridge

1.1Introducing the Modbus to Ethernet Bridge

1.1.1Bridge Applications

The Modicon Modbus to Ethernet Bridge provides a means for transacting messages between Ethernet TCP/IP devices and Modbus serial devices. It supports up to eight concurrent transactions between Modbus Master and Slave devices, handling the conversion of TCP/IP and Modbus RTU/ASCII protocols transparently to the user application.

Ethernet nodes using TCP/IP can function as Modbus Masters, originating messages to the Bridge for delivery to Modbus Slave devices connected to the Bridge's Modbus port. The Bridge forwards the messages to the Slave devices using Modbus RTU or ASCII protocol and returns their responses to the Master.

Figure 1 shows a typical application in which a Bridge connects two Modbus Masters on Ethernet to several Modbus Slave serial devices.

Figure 1 Bridging Between Ethernet and Modbus

Ethernet

Bridge

174 CEV 300 10

Modbus

The bridge also allows multiple Modbus networks to be linked together across an Ethernet connection. Multiple Bridges can furnish an Ethernet link between widely separated Modbus networks. This extends the message path beyond the cable lengths allowed for serial connections, and allows a Master on any Modbus network to access Slave devices on another network.

10

Image 10
Contents Modicon Page Breite 185 mm Höhe 230 mm Breite 178 mm Höhe 216 mm Page Preface Data, Illustrations, AlterationsPage Contents Using Panel Software GlossaryModbus to Ethernet Bridge CEV 300 Introducing the Modbus to Ethernet Bridge Bridge ApplicationsOverview Installation and Configuration Bridging Between Multiple Modbus Networks EthernetMapping for a Modbus Master Mapping Modbus and IP AddressesMapping for a Modbus Slave Modbus to Ethernet Bridge Front Panel Layout Modbus EthernetComponent Name Purpose Specifications Power Parameter SpecificationAgency Approval Parameter Specification Page Installing the Bridge Hardware Mounting the Bridge on the DIN Rail Before You Install the BridgeMounting the Bridge Connecting the Power Wiring Connecting the Power WiringConnecting the Serial Cable RJ45 Port Connecting the Serial Cable RJ45 PortCompatible Modbus Devices and Cables TSX NoteModbus Cable Pinouts References in this figure are to the devices listed in onDB to RJ45 Adapter Kits DB9M 110 XCA 203 ±Wire Connecting the Serial Cable Wiring TerminalsRS±485 RS±485 / RS±422 Setting the Serial Port Switch Setting the Serial Port SwitchConnecting the Ethernet Cable Connecting the Ethernet CableConfiguring the Bridge Safety Configuration OverviewBefore You Start Connecting by the RS±232 Port Example RS±232 Serial Terminal Emulator PropertiesConnecting by Telnet IP Address Not Assigned Telnet Host RequirementConnecting by Telnet IP Address Assigned Example Telnet ConnectionConfiguration Menu Using the Configuration MenuModbus Master Device Additional Menu Items Commands Default settings, Save, Quit without save Configuration Options 1Viewing and Changing Configuration Parameters Retaining the Current ValueSet Gateway IP Address Option 1 Network/IP SettingsIP Address Set NetmaskConfiguring the Bridge Serial Protocol Option 2 Serial and Mode SettingsAttached Device Interface TypeRTS/CTS Mode Option 3 Modem Control SettingsExample Option 4 Advanced Modbus Protocol Settings Slave AddressMessage Timeout Character TimeoutAllow Modbus Broadcasts How the Address Mapping Works Option 5 Unit ID to IP Address Mapping TableExample Address Mapping Adding a New Map Entry Entering New Address MappingExiting the Mapping Menu Deleting a Map EntryPage Using Panel Software Software Versions Using Concept or ModsoftModbus Slave Address WinTech Modscan Using Other SoftwareIntellution FIX MMI Worderware MMIPage Glossary Frame Default gatewayField Framing typesMAC Address InternetLayer NetworkRouter SwitchRepeater ServerUTP WinsockPage United States France Germany