Configuring the Bridge

0xFFFFFF00 or 255.255.255.0, using the lower 8 bits for the host part of the IP address. This allows up to 255 devices on the local subnetwork.

This default mask is the example shown in the menu above.

If the user desires to have multiple subnetworks with up to 32 devices on each the subnetwork mask could define 5 ªhostº bits or 255.255.255.224. With this setting, the decimal value 224 configures the lower 8 bits of the address, with the upper 3 of these bits addressing up to 8 subnetworks, and the lowest 5 bits forming the part of the address for the 32 local devices.

If you wish to specify a subnetwork mask, enter Y at the menu prompt and then enter your values for the mask.

Enter N to use the default subnetwork mask of 255.255.255.0.

37

Image 37
Contents Modicon Page Breite 185 mm Höhe 230 mm Breite 178 mm Höhe 216 mm Page Data, Illustrations, Alterations PrefacePage Contents Glossary Using Panel SoftwareModbus to Ethernet Bridge CEV 300 Bridge Applications Introducing the Modbus to Ethernet BridgeBridging Between Multiple Modbus Networks Ethernet Overview Installation and ConfigurationMapping for a Modbus Master Mapping Modbus and IP AddressesMapping for a Modbus Slave Modbus to Ethernet Bridge Modbus Ethernet Front Panel LayoutComponent Name Purpose Power Parameter Specification SpecificationsAgency Approval Parameter Specification Page Installing the Bridge Hardware Mounting the Bridge on the DIN Rail Before You Install the BridgeMounting the Bridge Connecting the Power Wiring Connecting the Power WiringConnecting the Serial Cable RJ45 Port Connecting the Serial Cable RJ45 PortTSX Note Compatible Modbus Devices and CablesReferences in this figure are to the devices listed in on Modbus Cable PinoutsDB to RJ45 Adapter Kits DB9M 110 XCA 203 ±Wire Connecting the Serial Cable Wiring TerminalsRS±485 RS±485 / RS±422 Setting the Serial Port Switch Setting the Serial Port SwitchConnecting the Ethernet Cable Connecting the Ethernet CableConfiguring the Bridge Safety Configuration OverviewBefore You Start Example RS±232 Serial Terminal Emulator Properties Connecting by the RS±232 PortTelnet Host Requirement Connecting by Telnet IP Address Not AssignedExample Telnet Connection Connecting by Telnet IP Address Assigned Configuration Menu Using the Configuration Menu Modbus Master Device Additional Menu Items Viewing and Changing Configuration Parameters Configuration Options 1Commands Default settings, Save, Quit without save Retaining the Current ValueIP Address Option 1 Network/IP SettingsSet Gateway IP Address Set NetmaskConfiguring the Bridge Attached Device Option 2 Serial and Mode SettingsSerial Protocol Interface TypeRTS/CTS Mode Option 3 Modem Control SettingsExample Slave Address Option 4 Advanced Modbus Protocol SettingsMessage Timeout Character TimeoutAllow Modbus Broadcasts How the Address Mapping Works Option 5 Unit ID to IP Address Mapping TableExample Address Mapping Exiting the Mapping Menu Entering New Address MappingAdding a New Map Entry Deleting a Map EntryPage Using Panel Software Software Versions Using Concept or ModsoftModbus Slave Address Intellution FIX MMI Using Other SoftwareWinTech Modscan Worderware MMIPage Glossary Field Default gatewayFrame Framing typesLayer InternetMAC Address NetworkRepeater SwitchRouter ServerWinsock UTPPage United States France Germany