SUPERSERVER
2-5 Checking the Serverboard Setup
After you install the
Accessing the Inside of the System (Figure 2-5)
1.First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").
2.Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops.
3.You can then lift the top cover from the chassis to gain full access to the inside of the server.
Checking the Components
1.You may have one or two processors already installed into the system board. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor and heatsink installation.
2.Your
3.If desired, you can install an
4.Make sure all power and data cables are properly connected and not blocking the airflow. See Chapter 5 for details on cable connections.
5.Check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the serverboard area of the chassis.