There is no corrective action to be taken other than to reduce the number of controls on the various screens that form the project, reprocess the whole project and download the modified files to the LANServer.

As a guideline it is suggested that the user budget 20-25 bytes per Sentry-Sensor. The actual number used per Sentry-Sensor is dependent on the length of the tag name and the length of the units field.

Appendix 1.8. Sentry Calibration Backup (SentryBK) produces a warning message on completion.

If the following warning dialog is produced on completion of the backup then the user needs to read and act on the following notes.

This warning is produced if the register 40977 is not backed-up. This register is one of the new registers backed-up in rev 1.03a of the control.

Depending on the configuration, this may be what is desired. However, if backing up the registers prior to a firmware change in the Sentry then take the following actions before changing the firmware.

1.Edit C:\Program Files\FST_SentryBK\index.txt and add the following lines to the file. If the file doesn’t exist, then ignore this step.

40159,8,

40977,8,

40985,8,

2.Browse to the web screen which contains the SentryBK control.

3.In the Internet Explorer menu, select VIEW, Source. Notepad will start and the html source code will be displayed.

4.Save the file to the computer

5.Find the list of registers which get backed up.

6.Add the new registers. Save the file.

7.Transfer the saved file back to the LANServer. (RuiNet –i192.168.1.81 –u1 – lfilename.htm) or back to the standard web-server that served the file.

Appendix 1.9. LANServer Configuration LED

When the error message "WEB:#26 Err. Cant open required file 'nodes.htm'". is printed, the configuration LED is turned on. This is done once each time the LANServer is reset.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 40
Contents Sentry LANServer Applicability & EffectivityTable of Contents LED1 Product Description General FeaturesOperation Sentry Firmware Version ConnectionsModel 5391-01 LANServer with 2-4 Sentry Controllers Page Quick Start LANServer Terminology Quick StartSetting Browser Security Settings for ActiveX controls Browser Security SettingsActiveX Controls and Security T12017-SentryLANServerUsersManual Customize the settings Setting the Browser Privacy Settings for Cookies Cookies and Browser SecuritySpecify the WebServer IP address and then click Allow T12017-SentryLANServerUsersManual Interpreting Zone Buttons T12017-SentryLANServerUsersManual Interpreting Sentry-Sensor Controls Interpreting Sentry -Combo Controls Interpreting Sentry Alarms Understanding the Alarm Table Colors Acknowledging AlarmsClick Retry to clear the dialog Interpreting Sentry Events Event Report TypesPage Understanding the Events What happens if Event Logging is disabled?Events Page and the Date / Time Potential Problems with Event Logging File Problems Space ProblemsEvent File Maintenance Limited number of event recordsManaging Sentry Events Uploading Potential Problems with an Upload How Event Time Stamps are reported Manual uploadInterpreting the Sentry Face Plate LED Current sensor number Gas Concentration for current sensor Sensor One User at a Time ActiveX Not InstalledLANServer Driver Ver .05f Required Description How the Control OperatesBackup File Contents Problems with Calibration Backup ControlInterpreting Analog, Text and LED controls Analog Controls Text ControlsLED Controls Using the LANServer to allow customers to upload files Appendix 1.3. Page login.htm not found Appendix 1.2. Objects report ‘Not Found’Appendix 1.6. Buttons Display in White Appendix 1.7. Cookie LengthAppendix 1.9. LANServer Configuration LED 40159,8 40977,8 40985,8Appendix 2. LANServer Error Messages FYIWEB#13 Err Not enough Space for alarm WEB#15 FYI ASO Max Limited to %d Web#68 FYI. Http Appendix 3. WinSock Error Messages Wsaeconnreset WsaenetresetWsaeafnosupport WsaealreadyWsaefault WsaedestaddrreqWsaehostdown WsaehostunreachWsaeisconn WsaemfileWsaemsgsize WsaenetdownWsaenotconn WsaenotsockWsaeopnotsupp WsaepfnosupportWsaeshutdown WsaesocktnosupportSockraw WsaetimedoutWsainvalidparameter WsainvalidproctableWsainvalidprovider WsaioincompleteWsanotinitialised WsanodataWsanorecovery HostsWsaproviderfailedinit WsasyscallfailureWINSOCK.DLL WsavernotsupportedWsaediscon WsaoperationabortedAppendix 4.2. LED1 Appendix 4. FieldServer ActiveX Controls Appendix 4.1. Ana1Appendix 4.3. Char1 Appendix 4.4. Limitations and Supported Environments Appendix 5. General Appendix 5.1 .1 Browser Caching This page Intentionally Left Blank