Sierra 5391-01, 5391-02 user manual Wsanotinitialised, Wsanodata

Page 53

T12017-Sentry_LANServer_Users_Manual

 

 

 

 

 

 

Page 53 of 59

 

 

 

 

 

 

 

 

 

 

 

 

Macro

Code

Message

 

Description

 

 

 

 

 

 

 

Invalid

 

 

A service provider returned a

 

 

WSAINVALIDPROCTABLE

OS

procedure table

bogus proc table to WS2_32.DLL.

 

 

dependent

from

service

(Usually caused by one or more of

 

 

 

 

 

 

 

provider

 

the function pointers being NULL.)

 

 

 

OS

Invalid

service

A service provider returned a

 

 

WSAINVALIDPROVIDER

provider version

 

 

 

dependent

number

 

 

version number other than 2.0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The application has tried to

 

 

 

 

 

 

 

determine the status of an

 

 

 

 

 

 

 

overlapped operation which is not

 

 

 

 

Overlapped

I/O

yet

completed.

Applications

that

 

 

WSA_IO_INCOMPLETE

OS

event object not

use

WSAGetOverlappedResult

 

 

dependent

in

signaled

(with the fWait flag set to false) in a

 

 

 

 

 

 

 

state

 

 

polling mode to determine when an

 

 

 

 

 

 

 

overlapped

operation

has

 

 

 

 

 

 

 

completed will get this error code

 

 

 

 

 

 

 

until the operation is complete.

 

 

 

 

 

 

 

 

The application has initiated an

 

 

 

 

Overlapped

 

overlapped operation which cannot

 

 

 

OS

 

be

completed

immediately.

A

 

 

WSA_IO_PENDING

operations

will

 

 

dependent

completion indication will be given

 

 

 

 

complete later

at a later time when the operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

has been completed.

 

 

 

 

 

 

 

 

An application used a Windows

 

 

 

OS

Insufficient

 

Sockets

function

which directly

 

 

WSA_NOT_ENOUGH_MEMORY

memory

 

maps to a Win32 function. The

 

 

dependent

 

 

 

 

 

available

 

Win32 function is indicating a lack

 

 

 

 

 

 

 

of required memory resources.

 

 

 

 

 

 

 

 

Either the application hasn't called

 

 

 

 

 

 

 

WSAStartup

or

WSAStartup

 

 

 

 

Successful

 

failed. The application may be

 

 

WSANOTINITIALISED

10093

WSAStartup

 

accessing

a socket which

the

 

 

not

 

yet

current active task does not own

 

 

 

 

 

 

 

 

 

performed

 

(i.e. trying to share a socket

 

 

 

 

 

 

 

between tasks),

or

WSACleanup

 

 

 

 

 

 

 

has been called too many times.

 

 

 

 

 

 

 

The requested name is valid and

 

 

 

 

 

 

 

was found in the database, but it

 

 

 

 

 

 

 

does not have the correct

 

 

 

 

 

 

 

associated data being resolved for.

 

 

 

 

 

 

 

The usual example for this is a

 

 

 

 

Valid name, no

hostname -> address translation

 

 

WSANO_DATA

11004

data record

of

attempt (using gethostbyname or

 

 

 

 

requested type

WSAAsyncGetHostByName)

 

 

 

 

 

 

 

 

which uses the DNS (Domain

 

 

 

 

 

 

 

Name Server), and an MX record is

 

 

 

 

 

 

 

returned but no A record -

 

 

 

 

 

 

 

indicating the host itself exists, but

 

 

 

 

 

 

 

is not directly reachable.

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 53
Contents Applicability & Effectivity Sentry LANServerTable of Contents LED1 Operation FeaturesProduct Description General Connections Sentry Firmware VersionModel 5391-01 LANServer with 2-4 Sentry Controllers Page Quick Start Quick Start LANServer TerminologyActiveX Controls and Security Browser Security SettingsSetting Browser Security Settings for ActiveX controls T12017-SentryLANServerUsersManual Customize the settings Cookies and Browser Security Setting the Browser Privacy Settings for CookiesSpecify the WebServer IP address and then click Allow T12017-SentryLANServerUsersManual Interpreting Zone Buttons T12017-SentryLANServerUsersManual Interpreting Sentry-Sensor Controls Interpreting Sentry -Combo Controls Interpreting Sentry Alarms Acknowledging Alarms Understanding the Alarm Table ColorsClick Retry to clear the dialog Event Report Types Interpreting Sentry EventsPage Events Page and the Date / Time What happens if Event Logging is disabled?Understanding the Events Space Problems Potential Problems with Event Logging File ProblemsEvent File Maintenance Limited number of event recordsManaging Sentry Events Uploading How Event Time Stamps are reported Manual upload Potential Problems with an UploadInterpreting the Sentry Face Plate LED Current sensor number Gas Concentration for current sensor Sensor LANServer Driver Ver .05f Required ActiveX Not InstalledOne User at a Time How the Control Operates DescriptionProblems with Calibration Backup Control Backup File ContentsInterpreting Analog, Text and LED controls Text Controls Analog ControlsLED Controls Using the LANServer to allow customers to upload files Appendix 1.2. Objects report ‘Not Found’ Appendix 1.3. Page login.htm not foundAppendix 1.7. Cookie Length Appendix 1.6. Buttons Display in White40159,8 40977,8 40985,8 Appendix 1.9. LANServer Configuration LEDFYI Appendix 2. LANServer Error MessagesWEB#13 Err Not enough Space for alarm WEB#15 FYI ASO Max Limited to %d Web#68 FYI. Http Appendix 3. WinSock Error Messages Wsaenetreset WsaeconnresetWsaeafnosupport WsaealreadyWsaedestaddrreq WsaefaultWsaehostdown WsaehostunreachWsaemfile WsaeisconnWsaemsgsize Wsaenetdown Wsaenotsock Wsaenotconn Wsaeopnotsupp WsaepfnosupportWsaesocktnosupport WsaeshutdownSockraw WsaetimedoutWsainvalidproctable WsainvalidparameterWsainvalidprovider WsaioincompleteWsanodata WsanotinitialisedHosts WsanorecoveryWsaproviderfailedinit WsasyscallfailureWsavernotsupported WINSOCK.DLLWsaediscon WsaoperationabortedAppendix 4.3. Char1 Appendix 4. FieldServer ActiveX Controls Appendix 4.1. Ana1Appendix 4.2. LED1 Appendix 4.4. Limitations and Supported Environments Appendix 5. General Appendix 5.1 .1 Browser Caching This page Intentionally Left Blank