Sierra 5391-01, 5391-02 Wsaeshutdown, Wsaesocktnosupport, Sockraw, Wsaetimedout, Wsatypenotfound

Page 51

T12017-Sentry_LANServer_Users_Manual

 

 

 

 

 

 

Page 51 of 59

 

 

 

 

 

 

 

 

 

 

 

 

 

Macro

Code

Message

 

Description

 

 

 

 

 

 

 

 

 

 

A request to send or receive data

 

 

 

 

 

 

was disallowed because the socket

 

 

 

 

 

 

had already been shut down in that

 

 

 

 

Cannot

send

direction with a previous shutdown

 

 

WSAESHUTDOWN

10058

after

socket

call. By calling shutdown a partial

 

 

 

 

shutdown

close of a socket is requested,

 

 

 

 

 

 

which is a signal that sending or

 

 

 

 

 

 

receiving or both has been

 

 

 

 

 

 

discontinued.

 

 

 

 

 

 

 

 

 

 

The support for the specified

 

 

 

 

 

 

socket type does not exist in this

 

 

 

 

Socket type not

address family. For example, the

 

 

WSAESOCKTNOSUPPORT

10044

optional

type

SOCK_RAW

might

 

 

 

 

supported

be selected in a socket call, and

 

 

 

 

 

 

 

 

 

 

 

 

the

implementation

does

not

 

 

 

 

 

 

support SOCK_RAW sockets at all.

 

 

 

 

 

 

A

connection

attempt

failed

 

 

 

 

 

 

because the connected party did

 

 

WSAETIMEDOUT

10060

Connection

not properly respond after a period

 

 

timed out

 

of time, or established connection

 

 

 

 

 

 

 

 

 

 

 

failed because connected host has

 

 

 

 

 

 

failed to respond.

 

 

 

 

 

WSATYPE_NOT_FOUND

10109

Class type not

The specified class was not found.

 

 

 

 

found

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This error is returned from

 

 

 

 

 

 

operations on non-blocking sockets

 

 

 

 

 

 

that

cannot

be

completed

 

 

 

 

 

 

immediately,

for

example

recv

 

 

 

 

 

 

when no data is queued to be read

 

 

 

 

Resource

from

the

socket. It is a non-fatal

 

 

 

 

error, and the operation should be

 

 

WSAEWOULDBLOCK

10035

temporarily

 

 

retried later.

It

is

normal for

 

 

 

 

unavailable

 

 

 

 

WSAEWOULDBLOCK

to

be

 

 

 

 

 

 

 

 

 

 

 

 

reported as the result from calling

 

 

 

 

 

 

connect

on

a

non-blocking

 

 

 

 

 

 

SOCK_STREAM socket, since

 

 

 

 

 

 

some time must elapse for the

 

 

 

 

 

 

connection to be established.

 

 

 

 

 

 

 

No such host is known. The name

 

 

 

 

 

 

is not an official hostname or alias,

 

 

 

 

 

 

or it cannot be found in the

 

 

 

 

 

 

database(s)

being queried.

This

 

 

WSAHOST_NOT_FOUND

11001

Host not found

error may also be returned for

 

 

 

 

 

 

protocol and service queries, and

 

 

 

 

 

 

means the specified name could

 

 

 

 

 

 

not be found in the relevant

 

 

 

 

 

 

database.

 

 

 

 

 

 

 

OS

Specified

event

An application attempts to use an

 

 

WSA_INVALID_HANDLE

object handle is

event object, but the specified

 

 

dependent

 

 

 

 

invalid

 

handle is not valid.

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 51
Contents Applicability & Effectivity Sentry LANServerTable of Contents LED1 Features Product Description GeneralOperation Connections Sentry Firmware VersionModel 5391-01 LANServer with 2-4 Sentry Controllers Page Quick Start Quick Start LANServer TerminologyBrowser Security Settings Setting Browser Security Settings for ActiveX controlsActiveX Controls and Security T12017-SentryLANServerUsersManual Customize the settings Cookies and Browser Security Setting the Browser Privacy Settings for CookiesSpecify the WebServer IP address and then click Allow T12017-SentryLANServerUsersManual Interpreting Zone Buttons T12017-SentryLANServerUsersManual Interpreting Sentry-Sensor Controls Interpreting Sentry -Combo Controls Interpreting Sentry Alarms Acknowledging Alarms Understanding the Alarm Table ColorsClick Retry to clear the dialog Event Report Types Interpreting Sentry EventsPage What happens if Event Logging is disabled? Understanding the EventsEvents Page and the Date / Time Limited number of event records Potential Problems with Event Logging File ProblemsSpace Problems Event File MaintenanceManaging Sentry Events Uploading How Event Time Stamps are reported Manual upload Potential Problems with an UploadInterpreting the Sentry Face Plate LED Current sensor number Gas Concentration for current sensor Sensor ActiveX Not Installed One User at a TimeLANServer Driver Ver .05f Required How the Control Operates DescriptionProblems with Calibration Backup Control Backup File ContentsInterpreting Analog, Text and LED controls Text Controls Analog ControlsLED Controls Using the LANServer to allow customers to upload files Appendix 1.2. Objects report ‘Not Found’ Appendix 1.3. Page login.htm not foundAppendix 1.7. Cookie Length Appendix 1.6. Buttons Display in White40159,8 40977,8 40985,8 Appendix 1.9. LANServer Configuration LEDFYI Appendix 2. LANServer Error MessagesWEB#13 Err Not enough Space for alarm WEB#15 FYI ASO Max Limited to %d Web#68 FYI. Http Appendix 3. WinSock Error Messages Wsaealready WsaeconnresetWsaenetreset Wsaeafnosupport Wsaehostunreach Wsaefault Wsaedestaddrreq WsaehostdownWsaenetdown WsaeisconnWsaemfile WsaemsgsizeWsaepfnosupport WsaenotconnWsaenotsock WsaeopnotsuppWsaetimedout WsaeshutdownWsaesocktnosupport SockrawWsaioincomplete WsainvalidparameterWsainvalidproctable WsainvalidproviderWsanodata WsanotinitialisedWsasyscallfailure WsanorecoveryHosts WsaproviderfailedinitWsaoperationaborted WINSOCK.DLLWsavernotsupported WsaedisconAppendix 4. FieldServer ActiveX Controls Appendix 4.1. Ana1 Appendix 4.2. LED1Appendix 4.3. Char1 Appendix 4.4. Limitations and Supported Environments Appendix 5. General Appendix 5.1 .1 Browser Caching This page Intentionally Left Blank