Sierra 5391-01, 5391-02 user manual Analog Controls, Text Controls

Page 35

T12017-Sentry_LANServer_Users_Manual

Page 35 of 59

5.13.1.Analog Controls

As the value in the Data Array changes the displayed value changes

The web page designer chose to have this analog value displayed in blue. If no color legend is supplied there is no significance to the color.

The web page designer configured this control to use a fixed number of pixels to display the analog value. (They could have let the display auto-size). When the value gets big enough, there are not enough pixels to display the correct number.

In this example, the value-12345 but only 20 pixels were allowed as the display width so the displayed number is truncated.

5.13.2.Text Controls

These controls are configured with the name of a Data Array in the LANServer and an offset into that array. If the value found at that location is zero then one text string, the so called ‘off’ text is displayed. If the value is non-zero then the so called ‘on’ text is displayed. The web project designer can also specify the following properties

Size: Limit the width of the control to a specific pixel count or allow the control to use as much space as is required to display the text. If a fixed pixel width has been specified then it’s possible that the displayed text will be truncated.

Colors: A different color for the ‘on’ and ‘off’ states can be configured.

Font family and font size.

Background color.

‘On’ and ‘Off’ Text.

The text displayed and color can change as the value found in the data Array changes.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 35
Contents Applicability & Effectivity Sentry LANServerTable of Contents LED1 Operation FeaturesProduct Description General Connections Sentry Firmware VersionModel 5391-01 LANServer with 2-4 Sentry Controllers Page Quick Start Quick Start LANServer TerminologyActiveX Controls and Security Browser Security SettingsSetting Browser Security Settings for ActiveX controls T12017-SentryLANServerUsersManual Customize the settings Cookies and Browser Security Setting the Browser Privacy Settings for CookiesSpecify the WebServer IP address and then click Allow T12017-SentryLANServerUsersManual Interpreting Zone Buttons T12017-SentryLANServerUsersManual Interpreting Sentry-Sensor Controls Interpreting Sentry -Combo Controls Interpreting Sentry Alarms Acknowledging Alarms Understanding the Alarm Table ColorsClick Retry to clear the dialog Event Report Types Interpreting Sentry EventsPage Events Page and the Date / Time What happens if Event Logging is disabled?Understanding the Events Limited number of event records Potential Problems with Event Logging File ProblemsSpace Problems Event File MaintenanceManaging Sentry Events Uploading How Event Time Stamps are reported Manual upload Potential Problems with an UploadInterpreting the Sentry Face Plate LED Current sensor number Gas Concentration for current sensor Sensor LANServer Driver Ver .05f Required ActiveX Not InstalledOne User at a Time How the Control Operates DescriptionProblems with Calibration Backup Control Backup File ContentsInterpreting Analog, Text and LED controls Text Controls Analog ControlsLED Controls Using the LANServer to allow customers to upload files Appendix 1.2. Objects report ‘Not Found’ Appendix 1.3. Page login.htm not foundAppendix 1.7. Cookie Length Appendix 1.6. Buttons Display in White40159,8 40977,8 40985,8 Appendix 1.9. LANServer Configuration LEDFYI Appendix 2. LANServer Error MessagesWEB#13 Err Not enough Space for alarm WEB#15 FYI ASO Max Limited to %d Web#68 FYI. Http Appendix 3. WinSock Error Messages Wsaealready WsaeconnresetWsaenetreset WsaeafnosupportWsaehostunreach WsaefaultWsaedestaddrreq WsaehostdownWsaenetdown WsaeisconnWsaemfile WsaemsgsizeWsaepfnosupport WsaenotconnWsaenotsock WsaeopnotsuppWsaetimedout WsaeshutdownWsaesocktnosupport SockrawWsaioincomplete WsainvalidparameterWsainvalidproctable WsainvalidproviderWsanodata WsanotinitialisedWsasyscallfailure WsanorecoveryHosts WsaproviderfailedinitWsaoperationaborted WINSOCK.DLLWsavernotsupported WsaedisconAppendix 4.3. Char1 Appendix 4. FieldServer ActiveX Controls Appendix 4.1. Ana1Appendix 4.2. LED1 Appendix 4.4. Limitations and Supported Environments Appendix 5. General Appendix 5.1 .1 Browser Caching This page Intentionally Left Blank