25
J5
Serial 1
J6
Serial 2
Figure 12. J5 and J6 Connectors layout
Both can be set as RS232 but only one (J5) can be set as RS422-485.
Refer to the following tables for the serial ports pinout assignment in RS232/422/485 modes.
Table 9. J5, J6 Serial Port Connectors in RS232 mode
Pin |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9,10 |
Signal |
DCD |
DSR |
RX |
RTS |
TX |
CTS |
DTR |
RI |
GND |
Function | DB25 | DB9 |
Data Carrier Detect | 8 | 1 |
Data Set Ready | 6 | 6 |
Receive Data | 3 | 2 |
Request To Send | 4 | 7 |
Transmit data | 2 | 3 |
Clear To Send | 5 | 8 |
Data Terminal | 20 | 4 |
Ready |
|
|
Ring Indicator | 22 | 9 |
Signal Ground | 7 | 5 |
Table 10. J5 Serial Port Connector in
|
| RS422 |
|
Pin | Signal | Function | In/out |
1 | Transmit data | out | |
2 | Not connected | ||
3 | +TX | Transmit Data | out |
4 | Not connected | ||
5 | Receive Data | in | |
6 | Not connected | ||
7 | +RX | Receive Data | in |
8 | Not connected | ||
9,10 | gnd | Signal ground |
| RS485 |
|
|
Signal | Function | In/out | Pin |
Transmit/Receive data | out/in | 1 | |
Not connected | 2 | ||
+TX/+RX | Transmit/Receive data | out/in | 3 |
Not connected | 4 | ||
Not connected | 5 | ||
Not connected | 6 | ||
Not connected | 7 | ||
Not connected | 8 | ||
gnd | Signal ground | 9,10 |
Note. If the Serial port is used in RS485 mode, the
This signal is defined by bit 0 of the UART Modem Control Register (MCR) and the bi- directional line is controlled as follows:
25