SMC Networks 1000 manual EC Conformance Declaration Class a

Page 8

COMPLIANCES

EC Conformance Declaration - Class A

SMC contact for these products in Europe is: SMC Networks Europe,

Edificio Conata II,

Calle Fructuós Gelabert 6-8, 2o, 4a, 08970 - Sant Joan Despí, Barcelona, Spain.

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/ EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

Limit class A according to EN 55022:1998

 

Limit class A for harmonic current emission according to

 

 

EN 61000-3-2/1995

 

Limitation of voltage fluctuation and flicker in low-voltage

 

 

supply system according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

 

Electrostatic Discharge according to EN 61000-4-2:1995

 

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to

 

 

EN 61000-4-3:1996

 

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

Electrical fast transient/burst according to EN 61000-4-4:1995

 

 

(AC/DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

Immunitytoconducteddisturbances,Inducedbyradio-frequency

 

 

fields: EN 61000-4-6:1996

 

 

(0.15 - 80 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

 

EN 61000-4-8:1993

 

 

(1 A/m at frequency 50 Hz)

 

Voltage dips, short interruptions and voltage variations

 

 

immunity test according to EN 61000-4-11:1994

 

 

(>95% Reduction @10 ms, 30% Reduction @500 ms, >95%

 

 

Reduction @5000 ms)

LVD:

• EN 60950 (A1/1992; A2/1993; A3/1993; A4/1995; A11/1997)

ii

Image 8
Contents TigerSwitch Page TigerSwitch Installation Guide Trademarks Limited Warranty Limited Warranty Compliances FCC Class aIndustry Canada Class a Japan Vcci Class aEC Conformance Declaration Class a Taiwan Bsmi Class a Australia AS/NZS 3548 1995 Class a IiiUnderwriters Laboratories Compliance Statement Safety ComplianceWarnhinweis Faseroptikanschlüsse Optische Sicherheit Wichtige Sicherheitshinweise Germany Compliances Table of Contents Troubleshooting A-1 Specifications C-1Making Network Connections Cables B-1Ordering Information D-1 Glossary Index Index-1 Table of Contents Chapter About Tigerswitch OverviewGbic Slots Description of Hardware1000BASE-T Ports Status LEDs Port and System LEDsNetwork Management Agent Spanning Tree Protocol VLANsOptional Redundant Power Unit Power Supply ReceptaclesMulticast Switching Traffic PriorityPerformance Features and BenefitsConnectivity Management Introduction to Switching Chapter Network PlanningSample Applications Backbone ConsolidationMaking Vlan Connections Making Vlan ConnectionsConnectivity Rules Mbps Gigabit Ethernet Collision DomainMaximum Fiber Optic Cable Distance for 1000BASE-SX Maximum Fiber Optic Cable Distance for 1000BASE-LXMaximum 100BASE-TX Network Diameter Using Repeaters Mbps Fast Ethernet Collision DomainSMC 3-2 Rule for Class II Repeaters SMC 2-1 Rule for Class I RepeatersApplication Notes Mbps Ethernet Collision DomainSMC 5-4-3 Rule Maximum Cable LengthInstalling the Switch Selecting a SiteOptional Rack-Mounting Equipment Equipment ChecklistPackage Contents Mounting Rack MountingAttaching the Brackets Desktop or Shelf Mounting Attaching the Adhesive FeetInstalling a Gbic Transceiver Connecting to a Power Source Power ReceptacleInstalling the Switch Connecting Network Devices Chapter Making Network ConnectionsConnecting to 1000BASE-T Devices Connecting to an SC-Type Fiber Port Maximum 1000BASE-LX Gigabit Ethernet Cable Length Power and Cooling Problems Appendix a TroubleshootingDiagnosing Switch Indicators Installation In-Band AccessSpecifications Appendix B CablesTwisted-Pair Cable and Pin Assignments 1000BASE-T Pin AssignmentsPin MDI Signal Name MDI-X Signal Name 1000BASE-T Cable Requirements Cable Testing for Existing Category 5 CableAdjusting Existing Category 5 Cabling Console Port Pin Assignments DB-9 Port Pin AssignmentsConsole Port to 9-Pin COM Port on PC Console Port to 25-Pin DTE Port on PCAppendix C Specifications Physical CharacteristicsSwitch Features Management Features StandardsWarranty SafetyCompliances EmissionsAppendix D Ordering Information Ordering Information Glossary Glossary-11000BASE-T Auto-NegotiationGlossary-2 Glossary-3 Glossary-4 Glossary-5 Glossary-6 Glossary-7 Virtual LAN VlanGlossary-8 Index Index-1Index-2 Index-3 Index-4 Page For Technical SUPPORT, Call