Medalist 17242, 13032, 10232, 8422 and 4312, Rev. A | 19 |
Alternate capacity and master/slave jumper settings
1. The drive is shipped with a jumper on pins 7 and 8. This configures the drive for master or single drive operation.
2.Consult your computer manual to determine whether your computer supports cable select.
3.Use this jumper setting only if the drive does not work with a jumper on pins 7 and 8.
4.Use this jumper setting if your computer fails to boot because it cannot recognize drives with more than 4,092 cylinders.
| ATA interface | |||
pin 1 | connector | |||
| 2 | 4 | 6 | 8 |
|
|
|
| |
connector | 1 | 3 | 5 7 |
Slave
Master or single drive1
Enable cable select 2
Master with
Limit capacity to 2.1 Gbytes (4,092 cylinders) 4
Figure 2. Alternate capacity jumper and master/slave jumper
2.4 Drive mounting
You can mount the drive in any orientation using four screws in the side- mounting holes or four screws in the
Important mounting precautions:
•Allow a minimum clearance of 0.030 inches (0.76 mm) around the entire perimeter of the drive for cooling.
•Use only
•The screws should be inserted no more than 0.22 inch (5.58 mm) into the bottom mounting holes and no more than 0.20 inch (5.0 mm) into the side mounting holes.
•Do not overtighten the mounting screws (maximum torque: 3
•Do not use a drive interface cable that is more than 18 inches (457 mm) long.