Medalist 17242, 13032, 10232, 8422 and 4312, Rev. A | 11 |
Sleep mode. The drive enters Sleep mode after receiving a Sleep command from the host. The heads are parked and the spindle is at rest. The drive leaves Sleep mode after it receives a Hard Reset or Soft Reset from the host. After receiving a reset, the drive exits Sleep mode and enters Active mode with all current translation parameters intact.
Idle and Standby timers. Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and begins counting down from its specified delay times to zero. If the standby timer reaches zero before any drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the drive accepts all commands and returns to Active mode when disc access is necessary.
1.8 Environmental tolerances
1.8.1 Ambient temperature
Operating | 0° to 55°C (32° to 131°F) |
Nonoperating |
Note. Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters). Operating ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
1.8.2 Temperature gradient
Operating | 20°C/hour (36°F/hour) max, without condensation |
Nonoperating | 20°C/hour (36°F/hour) max, without condensation |
1.8.3 Humidity |
| |
1.8.3.1 | Relative Humidity | |
Operating |
| 8% to 80% noncondensing (10% per hour max) |
Nonoperating | 5% to 95% noncondensing (10% per hour max) | |
1.8.3.2 | Wet bulb temperature | |
Operating |
| 29.4°C (84°F) max |