Word | Description | Value |
|
|
|
59 | Number of sectors transferred during a Read Multiple or Write | xxxxH |
| Multiple command |
|
|
|
|
Total number of | ST910021A = 195,371,568 | |
| (see Section 2.2 for related information) | ST980825A = 156,301,488 |
| ST96023A = 117,210,240 | |
|
| |
|
| ST94015A = 78,140,160 |
|
|
|
62 | Retired | 0000H |
|
|
|
63 | Multiword DMA active and modes supported (see note follow- | xx07H |
| ing this table) |
|
|
|
|
64 | Advanced PIO modes supported (modes 3 and 4 supported) | 0003H |
65 | Minimum multiword DMA transfer cycle time per word (120 | 0078H |
| nsec) |
|
|
|
|
66 | Recommended multiword DMA transfer cycle time per word | 0078H |
| (120 nsec) |
|
|
|
|
67 | Minimum PIO cycle time without IORDY flow control (240 | 00F0H |
| nsec) |
|
|
|
|
68 | Minimum PIO cycle time with IORDY flow control (120 nsec) | 0078H |
0000H | ||
75 | Queue depth | 0000H |
0000H | ||
80 | Major version number | 007EH |
81 | Minor version number | 0000H |
82 | Command sets supported | 346BH |
83 | Command sets supported | 7D01H |
84 | Command sets support extension | 4003H |
85 | Command sets enabled | 34xxH |
86 | Command sets enabled | 3xxxH |
87 | Command sets enable extension | 4003H |
88 | Ultra DMA support and current mode | xx3FH |
| (see note following this table) |
|
|
|
|
89 | Security erase time | 0000H |
|
|
|
90 | Enhanced security erase time | 0000H |
|
|
|
91 | Advanced power management value | 0040H |
|
|
|
92 | Master password revision code | FFFEH |
|
|
|
93 | Hardware reset value (see description following this table) | xxxxH |
|
|
|
94 | Auto acoustic management setting | xxxxH |
|
|
|
0000H | ||
|
|
|
128 | Security status | 0001H |
|
|
|
xxxxH | ||
|
|
|
26 | Momentus 7200.1 PATA Product Manual, Rev. C |