During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/write electronics are in
Table 3: | DC power |
|
| |
|
|
|
| |
Power dissipation | +5V input average (25° C) | |||
|
| |||
ST9500323CS and ST9320328CS | ST9250311CS and ST91603110CS | |||
|
| |||
|
|
| ||
Spinup (max) | 1 amp |
| ||
|
|
|
| |
Seek |
| 1.54 watts |
| |
|
|
| ||
IDEMA 3 Stream | 1.7 watts | 1.6 watts | ||
|
|
| ||
Idle, performance* | 1.5 watts |
| ||
|
|
|
| |
Idle, active* |
| 0.90 watts | 0.81 watts | |
|
|
| ||
Idle, low power mode* | 0.72 watts | 0.67 watts | ||
|
|
|
| |
Standby** |
| 0.40 watts |
| |
|
|
|
| |
Sleep |
| 0.40 watts |
| |
|
|
|
|
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.
**Standby power is measured at steady state (after 200ms from transition)
2.9.1.1Typical current profile
Figure 1. Typical +5V only startup and operation current profile
8 | Pipeline HD Mini Series SATA Product Manual, Rev. E |