Seagate ST373355SS State of the drive prior to testing, Invoking DST, Short and extended tests

Page 26

5.2.6.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

A Drive Not Ready condition is reported by the drive under the following conditions:

Motor will not spin

Motor will not lock to speed

Servo will not lock on track

Drive cannot read configuration tables from the disc

In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.

5.2.6.2.2Invoking DST

To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.

5.2.6.2.3Short and extended tests

DST has two testing options:

1.short

2.extended

These testing options are described in the following two subsections.

Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.

Short test (Function Code: 001b)

The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.

Extended test (Function Code: 010b)

The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.

The anticipated length of the Extended test is reported through the Control Mode page.

5.2.6.2.4Log page entries

When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param- eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:

1. The Function Code field is set to the same value as sent in the DST command

20

Cheetah T10 SAS Product Manual, Rev. A

Image 26
Contents Cheetah T10 SAS Page Contents Seagate Technology support services Defect and error managementInstallation Interface requirementsList of Figures Cheetah T10 SAS Product Manual, Rev. a Scope Cheetah T10 SAS disc driveCheetah T10 SAS Product Manual, Rev. a Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance Reference documents Cheetah T10 SAS Product Manual, Rev. a General description Performance Standard featuresMedia description Formatted capacities Factory-installed accessoriesReliability Programmable drive capacityOptions factory installed User-installed accessoriesAccess time Performance characteristicsInternal drive characteristics Seek timeStart/stop time Format command execution time minutesGeneral performance characteristics Prefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationRecoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenance Controlling S.M.A.R.T Hot plugging the drive 4 S.M.A.R.T Performance impactPredictive failures Reporting controlDetermining rate Thermal monitorReference Temperature Temperature Log Page 0DhPrimary Temperature Parameter Code DescriptionShort and extended tests State of the drive prior to testingInvoking DST Short test Function Code 001bShipping Product warrantyAbort Product repair and return informationCheetah T10 SAS Product Manual, Rev. a DC power requirements Physical/electrical specificationsAC power requirements ST3300555SS DC power requirementsST3146755SS Gbit mode Amps ST3146755SS DC power requirementsST373355SS DC power requirements ST373355SS Gbit mode AmpsConducted noise immunity General DC power requirement notesPower sequencing Current profilesTypical ST3300555SS drive current profiles Typical ST3146755SS drive current profiles Typical ST373355SS drive current profiles ST3300555SS in 1.5 Gbit operation Power dissipationST3300555SS in 3 Gbit operation ST3146755SS in 3 Gbit operation ST3146755SS in 1.5 Gbit operationST373355SS in 3 Gbit operation ST373355SS in 1.5 Gbit operationTemperature a. Operating Environmental limitsShock and vibration Relative humidityEffective altitude sea level a. Operating ShockPackage size Packaged/product weight Drop height Recommended mountingCorrosive environment Air cleanlinessVibration a. Operating-normal Mechanical specifications AcousticsDrive error recovery procedures Defect and error managementDrive internal defects/errors Write retry count LBA cumulative, msec Media Pre-Scan SAS system errorsBackground Media Scan Deferred Auto-Reallocation Idle Read After WriteInstallation Drive orientationCooling Air flowDrive mounting GroundingCheetah T10 SAS Product Manual, Rev. a SAS features Interface requirementsDual port support Command name Command code Supported Scsi commands supportedCommands supported by Cheetah T10 SAS family drives Commands supported by Cheetah T10 SAS family drives Commands supported by Cheetah T10 SAS family drives Commands supported by Cheetah T10 SAS family drives Cheetah T10 SAS inquiry data Mode Sense dataInquiry data Bytes Data hexPage ST3300555SS Mode Sense data Mode PagesST3146755SS Mode Sense data ST373355SS Mode Sense data Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusSAS physical interface Datum B Physical characteristics Connector requirementsPin descriptions Pin Signal name Signal typeElectrical description SAS pin descriptionsSAS transmitters and receivers Signal characteristicsPower Ready LED OutGeneral interface characteristics LED drive signalDifferential signals Eye masks Eye masks overviewAbsolute amplitude Receive eye maskJitter tolerance masks Normalized time in UIJitter Peak-toSinusoidal Frequency in kHzTransmitter signal characteristics Signal characteristica Units GbpsMaximum allowable jitter Receiver signal characteristicsSignal characteristic Units Gbps Gbps m, n Deterministic jitterqCompliant jitter test pattern Cjtpat Impedance specificationsReceiver jitter tolerance Impedance requirements Sheet 1Electrical TxRx connections Transmitter characteristicsImpedance requirements Sheet 2 = -5,437dB Shows the zero-length test load Receiver characteristics Cheetah T10 SAS Product Manual, Rev. a Internet MySeagate Spp.seagate.com Seagate Technology support servicesWarranty Service Presales SupportData Recovery Services Authorized Service Centers Data Recovery ServicesToll-free support numbers FAX services-All Europe toll callCall center Presales and Technical Support Warranty Service Africa/Middle East support services Index NumericsPage SAS See also cooling Page Seagate Technology LLC