14 | Cheetah 73LP Product Manual, Rev. E |
error (15h) is reported with a Medium error (3h) or Hardware error (4h) reported in the Sense Key. This is an unrecoverable seek error. Unrecoverable seek errors are classified as failures for MTBF calculations. Refer to the SCSI Interface Product Manual, part number 75789509, for Request Sense information.
5.2Reliability and service
You can enhance the reliability of Cheetah 73LP disc drives by ensuring that the drive receives adequate cool- ing. Section 6.0 provides recommended
5.2.1Mean time between failure (MTBF)
The production disc drive achieves an MTBF of 1,200,000 hours when operated in an environment that ensures the case temperatures specified in Section 6.4.1 are not exceeded.
The MTBF target is specified as device
The following expression defines MTBF:
MTBF per measurement period = Estimated
Number of drive failures in the period
Estimated
MTBF is based on the following assumptions:
•8,760
•250 average on/off cycles per year
•Operating at nominal voltages
•System provides adequate cooling to ensure the case temperatures specified in Section 6.4.1 are not exceeded.
Drive failure means any stoppage or failure to meet defined specifications caused by drive malfunction.
A S.M.A.R.T. predictive failure indicates that the drive is deteriorating to an imminent failure and is considered an MTBF hit.
5.2.2Preventive maintenance
No routine scheduled preventive maintenance is required.
5.2.3Service life
The drive has a useful service life of five years. Depot repair or replacement of major parts is permitted during the lifetime.
5.2.4Service philosophy
Special equipment is required to repair the drive HDA. To achieve the above service life, repairs must be per- formed only at a properly equipped and staffed Seagate service and repair facility. Troubleshooting and repair of PCBs in the field is not recommended because of the extensive diagnostic equipment required for effective servicing. There are not spare parts available for this drive. The drive warranty is voided if the HDA is opened.
5.2.5Service tools
No special tools are required for site installation or recommended for site maintenance. Refer to Section 5.2.4. The depot repair philosophy of the drive precludes the necessity for special tools. Field repair of the drive is not practical because users cannot purchase individual parts for the drive.