Perle Systems S-1110-XT manual Fiber Fault Alert Switch, Switch Position Fiber Port

Page 6

Fiber Fault Alert (Switch 3)

Switch Position

Fiber Port

 

 

Up (default)

Enabled

 

 

Down

Disabled

 

 

Enabled: If the media converter detects a loss of signal on the fiber receiver, it will immediately disable its fiber transmitter signal on the same port. This, in effect, notifies the fiber link partner that an error condition exists on the fiber connection.

If the remote media converter is set up for Fiber Fault Alert (FFA) and the local media converter is set up with Link Pass-Through, a loss of fiber link will be passed through to the local copper connection thus notifying the connected device.

If the media converter has been set to Smart Link Pass-Through mode, the effect will be the same as FFA, since the link loss on the fiber receiver will result in bringing down the copper link, which will in turn cause the transmit fiber link to be brought down.

Note: This feature only takes effect if Fiber Negotiation has been turned off.

Disabled: The media converter will not monitor for or generate Fiber Fault Alert.

6Perle 10/100/1000 Ethernet Extended Temperature Media Converter Installation Guide

Image 6
Contents Installation Guide 1110-XT Model Connector Wavelength Distance OverviewInstallation Auto-MDIX Jumper SettingsAuto Negotiation copper Switch DIP SwitchesDIP Switch Settings Switch Position CopperLink Mode Switch Switch Position ModeFiber Fault Alert Switch Switch Position Fiber PortDuplex copper Switch Switch Position Copper portIllustration of the FFA Full/Half Duplex on Fiber Switch Speed copper SwitchAuto Fiber Negotiation Switch Switch Fiber Position Mbps Up default Auto Down OffInstalling the Duplex Fiber Cable Loopback Fiber-1 SwitchInstalling the SFP Fiber Module Installing the Simplex Fiber Cable Installing the Copper CableGrounding the Media Converter Powering up the Perle Media Converter Operation Status LEDLED Pattern Troubleshooting General No connectivityTechnical Specifications Mtbf SC/ST ModelsMtbf SFP Models Fiber Optic Specifications BudgetCompliance Information Warranty / RegistrationEN 55024, Class a Laser Safety IEC Contacting Technical Support Copyright