I/O UDP Settings

Configure the following parameters:

UDP Entry

When enabled, broadcasts I/O status (data) to the specified range of IP

 

addresses.

 

Default: Disabled

Start IP Address

The first host IP address in the range of IP addresses (for IPV4 or IPV6) that

 

the IOLAN will listen for messages from and/or send messages to.

End IP Address

The last host IP address in the range of IP addresses (for IPV4, not required for

 

IPV6) that the IOLAN will listen for messages from and/or send messages to.

Port

The UDP port that the IOLAN will use to relay messages to servers/hosts.

 

Default: 0 (zero)

Temperature Functionality

Overview

The Temperature tab configures the temperature scale settings for T4 models.

Field Descriptions

Configure the following parameter:

Temperature Scale Select the temperature scale that will be used to display temperature data. Data Options: Fahrenheit or Celsius

Default: Celsius

134

IOLAN DS1/TS2 User’s Guide, Version 3.4

Image 134
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents Configuration Methods DHCP/BOOTP Getting Started Configuring Serial Ports Console Management Profile Configuring Users Configuring Security UDP Configuring the System Controlling the I/O Channels Appendix a Virtual Modem AT Commands Appendix D I/O Wiring Diagrams Appendix G Troubleshooting Intended Audience PrefaceAbout This Book DocumentationTypeface Conventions Online HelpIolan Family Models IntroductionAbout the Iolan Iolan Features HardwareSoftware SecurityIolan Features Iolan Components ConnectivityIntroduction Desktop Models Power Supply SpecificationsGetting to Know Your Iolan OverviewDS1 Serial ActivityTop View End ViewSerial Mode Console/Serial SwitchConsole Mode Models Powering Up the IolanSerial Only Models Configuration Methods Chapter Requires a Configured IP Address Configuration Methods OverviewConfigures an IP Address Easy Config Wizard Connecting to the Iolan Using DeviceManager Access PlatformsUnique Features DeviceManagerDeviceManager Using DeviceManager Connecting to the Iolan Using WebManager WebManagerUsing WebManager Through the Network Command Line InterfaceConnecting to the Iolan Using the CLI Menu Using the CLIConnecting to the Iolan Using the Menu Through the Serial PortUsing the Menu Connecting to the Iolan Using DHCP/BOOTP Using DHCP/BOOTPDHCP/BOOTP Parameters Connecting to the Iolan Using Snmp SnmpUsing the Snmp MIB Snmp Easy Configuration Wizard Getting StartedSetting Up the Network Using a Direct Serial Connection to Specify an IP Address Using a Direct Serial Connection to Enable BOOTP/DHCPSet server internet dhcp/bootp on Using ARP-Ping For an IPv6 NetworkSetting Up the Serial Ports Setting Up the Serial Ports Setting Up Users Using DeviceManager WebManager Navigating DeviceManager/WebManager DeviceManagerWebManager Using DeviceManager to Connect to the Iolan Starting a New SessionAssigning a Temporary IP Address to a New Iolan Adding/Deleting Manual IOLANs Logging in to the IolanCreating a New Iolan Configuration in DeviceManager Using WebManager to Connect to the IolanConfiguration Files Logging into the IolanManaging the Iolan Opening an Existing Configuration FileImporting an Existing Configuration File Network Settings Overview IP SettingsIP Settings Field DescriptionsAutomatically server Default Enabled AdvancedFunctionality AdvancedHost Table Adding/Editing a Host Route ListAdding/Editing Routes Serial Ports FunctionalityEditing a Serial Port Resetting a Serial Port Hardware Tab Field Descriptions Serial Port ProfilesCommon Tabs Default Auto Flow Control Default NoneDefault Full Enable InboundPacket Forwarding Tab Field Descriptions Packet Definition Enable Trigger1Enable Trigger2 Packet SizeConsole Management Profile Protocol Listen for Connections on TCP Port Default TelnetGeneral Tab Field Descriptions Data Options IPv4 AddressAdvanced Tab Field Descriptions Dial Dial TimeoutBreak Handling Dial OutTruePort Profile TCP Port System Default Enabled Host NameConnect to remote Connect toHosts to connect to Host and backupAdding/Editing Additional TruePort Hosts Define a primaryPrimary Host Backup HostAdding/Editing a Multihost Entry Session Timeout Signals highDay Motd Default Disabled Idle Timeout WhenTCP Sockets Profile General Tab Field Descriptions Adding/Editing Additional Hosts Adding/Editing a Multihost Entry Enable TCP KeepaliveUDP Sockets Profile This entry is disabled since Direction is set to Disabled End IP Address Listen for connections on UDP port DirectionStart IP Address AutolearnAny Port Default 0 zeroTerminal Profile PortTVI925 Default DumbVT100 VT320 specifically supporting VT320-7Protocol When any data isDay Motd Default Disabled AutomaticallyDisconnect User logs out Default Disabled Data RangeTelnet Settings User Service SettingsLogin Settings Erase InterruptQuit EchoSerial Serial Tunneling ProfileSerial Server Tunnel Client Iolan TunnelServer Client Default Disabled Host NameAct As Tunnel Virtual Modem Profile 100 Iolan DS1/TS2 User’s Guide, Version DTR Signal Acts as RTS Signal Always On RTS Signal Acts as Phone Number to Host Mapping Phone Number Control Signal I/O ProfileVModem Phone Number Entry Host IP AddressDescription Input Signal Field DescriptionsInvert Signal LatchMode Default Disabled Syslog Output Signal Field DescriptionsAuto Clear Mode Manual ClearModbus Gateway Profile Destination Slave Settings Button Modbus/RTUMode IP MappingsAdvanced Field Descriptions Default 30 msDefault 1000 ms UID Start Modbus Slave IP Settings Field DescriptionsAdding/Editing Modbus Slave IP Settings UID End Default HostDefault TCP Data Options TCP or UDPModbus Slave Advanced Settings Field Descriptions Custom Application Profile General Tab Field DescriptionNetwork Advanced Serial Settings TabClosing Serial Port Default Disabled Deny Multiple MonitorName Name of the modem Modems TabAdding/Editing a Modem TruePort Baud Rate Tab Field Definitions116 Iolan DS1/TS2 User’s Guide, Version Configuring Users User Settings Adding/Editing Users General TabDefault Normal LevelDefault DSPrompt Services TabService Host IPLanguage Default EnglishAdvanced Tab Sessions Tab Session 1, 2, 3 ConnectSerial Port Access Tab 126 Iolan DS1/TS2 User’s Guide, Version Configuring Security ServicesField Descriptions Configuring I/O InterfacesChapter Settings Access FunctionalityAdvanced Slave Modbus Settings Default 30 seconds Failsafe Timer FunctionalityTimeout Failsafe Action is triggeredUDP Functionality Enable UDPBroadcast of I/O Default Disabled Status Default Celsius Temperature FunctionalityUDP Settings UDP EntryChannels AnalogDefault Current Alarm SettingsDigital Input Digital I/OInput Mode 139 Digital Output Default Manual Output ModeDefault Sink OutputDelay Pulse ModeInactive Signal Width Active Signal Width Pulse CountMonitoring Device Server RelayRelay I/O Application Industrial FreezersInactive Signal WidthActive Signal Temperature Default RTD Alarm Settings Basic Analog Alarm SettingsTrigger Type Advanced Analog Alarm SettingsClear Mode ClearTotal Data Length Exists UDP Unicast FormatAnalog Data Digital/Relay Data Serial Pin Signal DataUDP Unicast Example Length DataModbus Serial Application Connected to the Network Modbus SlaveModbus Serial Application Connected to the Serial Port Function Codes Modbus I/O AccessModbus TCP Application Coil/Register Descriptions Data Model A1/T1 A2/T2 A3/T3 A4/T4 Holding Registers Serial Port Coil/Register DescriptionsA4/T4 Registers Input RegistersA4D2/A4R2 Registers Data Model D1/R1 D2/R2 CoilsData Model D3/R1 D4/R2 Coils Serial Pin SignalsD4/D2R2 Registers Data Model Pin CoilsTruePort/Modbus Combination Modbus Serial Application TruePort Power Digital OutputTruePort I/O PC running aPC running Custom Application API TruePort Power Digital OutputAPI Over TruePort Only Introduction Accessing I/O Data Via TruePortSetup Command Format Format of API CommandsGet Commands Response FormatSet Commands Example 1 Turn on the first relay on a D2R2 unit Successful Response FormatUnsuccessful Response Format Example 2 Turn on the first and second relay on a D2R2 unitError Codes Snmp TrapsSyslog Configuring the System ChapterAlerts Management Custom App/Plugin Login Tab Field Descriptions Field DescriptionBootup Files Tab Field Descriptions Message of the Day Motd Tab Field Descriptions Tftp Tab Field DescriptionsControlling the I/O Channels Activate Output Manually activates the channel output Saving Configuration Files System Administration ChapterManaging Configuration Files Downloading Configuration FilesServer Name Downloading Configuration Files to Multiple IOLANsReboot Server Uploading Configuration Files Downloading Iolan FirmwareCalibrating Analog Input Calibrating Temperature InputCalibrating I/O Calibrating Analog Channels Calibrating RTDResetting Calibration Data Setting the IOLAN’s Date and TimeRebooting the Iolan Loading a Supplied Language Resetting the Iolan to Factory DefaultsLanguage Support Software Upgrades and Language Files Translation GuidanceDownloading Terminal Definitions Creating Terminal Definition FilesResetting Configuration Parameters For exampleLost Admin Password 184 Iolan DS1/TS2 User’s Guide, Version Commands Virtual Modem Initialization CommandsAT&Cn AT&SnAT&Rn DB25 Male Pinouts and Cabling DiagramsSerial Pinouts DB25 Female RJ45 GND CTSDB9 Male Serial Only DB9 Male I/ODB25 Male EIA-232 Cabling DiagramsTerminal DB25 Connector DB25 Female10-pin Pin RJ45DB9 Male Modem DB25 Connector Iolan RJ45 DCERxD TxD DTR 20 DTR GND Iolan DB25 Male/Female Setting JumpersPort Iolan Iolan RJ45 DIP Digital I/O Module Analog Input Module 200 Iolan DS1/TS2 User’s Guide, Version Digital Input Wet Contact Wiring I/O DiagramsDigital I/O Digital Input Dry ContactDigital Output Sink Digital Output SourceCurrent Temperature InputAnalog Input VoltageRTD 4-Wire RTD 2-WireRTD 3-Wire Relay OutputNormally Closed Contact 206 Iolan DS1/TS2 User’s Guide, Version TruePort Utility TruePortAPI Response Format API I/O Access Over TruePortAPI Request Format Error Codes 210 Iolan DS1/TS2 User’s Guide, Version Accessories Starter Kit Adapters/CableRJ45F to DB25M DTE Crossover Adapter RJ45F DB25M DTERJ45F to DB25M DCE Modem Adapter RJ45F to DB25F DTE Crossover Adapter RJ45F DB25FRJ45F to DB9M DTE Crossover Adapter Sun/Cisco RJ45M Connector Cable for Rack Mount Models RJ45F to DB9F DTE Crossover AdapterCommunication Issues TroubleshootingHardware Problems Power/Ready LED continues to flash green in Desktop modelsLogin Problems DeviceManager ProblemsHost Problems Problems with Terminals Unknown IP AddressLong Reboot Cycle DHCP/BOOTP ProblemsLanguage Problems ModelsGlossary Authentication Dial Users Services Reverse Connection PAP PasswordAuthentication Protocol Radius Remote RIP RoutingBootp IndexSnmp
Related manuals
Manual 246 pages 24.21 Kb Manual 88 pages 61.31 Kb Manual 122 pages 55.83 Kb

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.