Perle Systems TS2, DS1 manual TruePort Profile, Overview

Page 78

Serial Port Profiles

TruePort Profile

Overview

TruePort is COM Port redirector that is supplied with the IOLAN. TruePort can be installed as a client on a Workstation or Server and supports a variety of operating systems. It, in conjunction with the IOLAN, emulates a local serial port (COM port), to the application, to provide connectivity to a remote serial device over the network. The TruePort profile operates in conjunction with the TruePort software.

Functionality

TruePort is a COM port redirector utility for the IOLAN. It can be run in two modes (these modes will be set on the client software when it is configured):

zTruePort Full mode—This mode allows complete device control and operates as if the device was directly connected to the Workstation/Server’s local serial port. It provides a complete COM port interface between the attached serial device and the network. All serial controls, baud rate control, etc., are sent to the IOLAN and replicated on its associated serial port.

zTruePort Lite mode—This mode provides a simple raw data interface between the application and the remote serial port. Although the port will still operate as a COM port, control signals are ignored. In this mode, the serial communications parameters must be configured on the IOLAN.

See the TruePort User’s Guide for more details about the TruePort client software.

78

IOLAN DS1/TS2 User’s Guide, Version 3.4

Image 78
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents Configuration Methods DHCP/BOOTP Getting Started Configuring Serial Ports Console Management Profile Configuring Users Configuring Security UDP Configuring the System Controlling the I/O Channels Appendix a Virtual Modem AT Commands Appendix D I/O Wiring Diagrams Appendix G Troubleshooting Intended Audience PrefaceAbout This Book DocumentationTypeface Conventions Online HelpIntroduction About the IolanIolan Family Models Iolan Features HardwareSoftware SecurityIolan Features Connectivity IntroductionIolan Components Desktop Models Power Supply SpecificationsGetting to Know Your Iolan OverviewDS1 Serial ActivityTop View End ViewConsole/Serial Switch Console ModeSerial Mode Powering Up the Iolan Serial Only ModelsModels Configuration Methods Chapter Configuration Methods Overview Configures an IP AddressRequires a Configured IP Address Easy Config Wizard Connecting to the Iolan Using DeviceManager Access PlatformsUnique Features DeviceManagerDeviceManager Using DeviceManager Connecting to the Iolan Using WebManager WebManagerUsing WebManager Command Line Interface Connecting to the Iolan Using the CLIThrough the Network Menu Using the CLIConnecting to the Iolan Using the Menu Through the Serial PortUsing the Menu Connecting to the Iolan Using DHCP/BOOTP Using DHCP/BOOTPDHCP/BOOTP Parameters Connecting to the Iolan Using Snmp SnmpUsing the Snmp MIB Snmp Easy Configuration Wizard Getting StartedSetting Up the Network Using a Direct Serial Connection to Specify an IP Address Using a Direct Serial Connection to Enable BOOTP/DHCPSet server internet dhcp/bootp on Using ARP-Ping For an IPv6 NetworkSetting Up the Serial Ports Setting Up the Serial Ports Setting Up Users Using DeviceManager WebManager Navigating DeviceManager/WebManager DeviceManagerWebManager Using DeviceManager to Connect to the Iolan Starting a New SessionAssigning a Temporary IP Address to a New Iolan Adding/Deleting Manual IOLANs Logging in to the IolanCreating a New Iolan Configuration in DeviceManager Using WebManager to Connect to the IolanConfiguration Files Logging into the IolanOpening an Existing Configuration File Importing an Existing Configuration FileManaging the Iolan Network Settings Overview IP SettingsIP Settings Field DescriptionsAutomatically server Default Enabled AdvancedAdvanced Host TableFunctionality Adding/Editing a Host Route ListAdding/Editing Routes Serial Ports FunctionalityEditing a Serial Port Resetting a Serial Port Serial Port Profiles Common TabsHardware Tab Field Descriptions Default Auto Flow Control Default NoneDefault Full Enable InboundPacket Forwarding Tab Field Descriptions Packet Definition Enable Trigger1Enable Trigger2 Packet SizeConsole Management Profile Protocol Listen for Connections on TCP Port Default TelnetGeneral Tab Field Descriptions Data Options IPv4 AddressAdvanced Tab Field Descriptions Dial Dial TimeoutBreak Handling Dial OutTruePort Profile TCP Port System Default Enabled Host NameConnect to remote Connect toHosts to connect to Host and backupAdding/Editing Additional TruePort Hosts Define a primaryBackup Host Adding/Editing a Multihost EntryPrimary Host Session Timeout Signals highDay Motd Default Disabled Idle Timeout WhenTCP Sockets Profile General Tab Field Descriptions Adding/Editing Additional Hosts Adding/Editing a Multihost Entry Enable TCP KeepaliveUDP Sockets Profile This entry is disabled since Direction is set to Disabled End IP Address Listen for connections on UDP port DirectionStart IP Address AutolearnAny Port Default 0 zeroTerminal Profile PortTVI925 Default DumbVT100 VT320 specifically supporting VT320-7Protocol When any data isDay Motd Default Disabled AutomaticallyDisconnect User logs out Default Disabled Data RangeUser Service Settings Login SettingsTelnet Settings Erase InterruptQuit EchoSerial Serial Tunneling ProfileSerial Server Tunnel Client Iolan TunnelClient Default Disabled Host Name Act As TunnelServer Virtual Modem Profile 100 Iolan DS1/TS2 User’s Guide, Version DTR Signal Acts as RTS Signal Always On RTS Signal Acts as Phone Number to Host Mapping Phone Number Control Signal I/O ProfileVModem Phone Number Entry Host IP AddressDescription Input Signal Field DescriptionsInvert Signal LatchMode Default Disabled Syslog Output Signal Field DescriptionsAuto Clear Mode Manual ClearModbus Gateway Profile Destination Slave Settings Button Modbus/RTUMode IP MappingsDefault 30 ms Default 1000 msAdvanced Field Descriptions Modbus Slave IP Settings Field Descriptions Adding/Editing Modbus Slave IP SettingsUID Start UID End Default HostDefault TCP Data Options TCP or UDPModbus Slave Advanced Settings Field Descriptions Custom Application Profile General Tab Field DescriptionNetwork Advanced Serial Settings TabClosing Serial Port Default Disabled Deny Multiple MonitorModems Tab Adding/Editing a ModemName Name of the modem TruePort Baud Rate Tab Field Definitions116 Iolan DS1/TS2 User’s Guide, Version Configuring Users User Settings Adding/Editing Users General TabDefault Normal LevelDefault DSPrompt Services TabService Host IPDefault English Advanced TabLanguage Sessions Tab Session 1, 2, 3 ConnectSerial Port Access Tab 126 Iolan DS1/TS2 User’s Guide, Version Configuring Security ServicesField Descriptions Configuring I/O InterfacesChapter Settings Access FunctionalityAdvanced Slave Modbus Settings Default 30 seconds Failsafe Timer FunctionalityTimeout Failsafe Action is triggeredEnable UDP Broadcast of I/O Default Disabled StatusUDP Functionality Default Celsius Temperature FunctionalityUDP Settings UDP EntryChannels AnalogDefault Current Alarm SettingsDigital Input Digital I/OInput Mode 139 Digital Output Default Manual Output ModeDefault Sink OutputDelay Pulse ModeInactive Signal Width Active Signal Width Pulse CountMonitoring Device Server RelayRelay I/O Application Industrial FreezersInactive Signal WidthActive Signal Temperature Default RTD Alarm Settings Basic Analog Alarm SettingsTrigger Type Advanced Analog Alarm SettingsClear Mode ClearUDP Unicast Format Analog DataTotal Data Length Exists Digital/Relay Data Serial Pin Signal DataUDP Unicast Example Length DataModbus Slave Modbus Serial Application Connected to the Serial PortModbus Serial Application Connected to the Network Modbus I/O Access Modbus TCP ApplicationFunction Codes Coil/Register Descriptions Data Model A1/T1 A2/T2 A3/T3 A4/T4 Holding Registers Serial Port Coil/Register DescriptionsA4/T4 Registers Input RegistersA4D2/A4R2 Registers Data Model D1/R1 D2/R2 CoilsData Model D3/R1 D4/R2 Coils Serial Pin SignalsD4/D2R2 Registers Data Model Pin CoilsTruePort/Modbus Combination Modbus Serial Application TruePort Power Digital OutputTruePort I/O PC running aPower Digital Output API Over TruePort OnlyPC running Custom Application API TruePort Accessing I/O Data Via TruePort SetupIntroduction Command Format Format of API CommandsGet Commands Response FormatSet Commands Example 1 Turn on the first relay on a D2R2 unit Successful Response FormatUnsuccessful Response Format Example 2 Turn on the first and second relay on a D2R2 unitError Codes Snmp TrapsConfiguring the System Chapter AlertsSyslog Management Custom App/Plugin Login Tab Field Descriptions Field DescriptionBootup Files Tab Field Descriptions Message of the Day Motd Tab Field Descriptions Tftp Tab Field DescriptionsControlling the I/O Channels Activate Output Manually activates the channel output Saving Configuration Files System Administration ChapterManaging Configuration Files Downloading Configuration FilesDownloading Configuration Files to Multiple IOLANs Reboot ServerServer Name Uploading Configuration Files Downloading Iolan FirmwareCalibrating Temperature Input Calibrating I/OCalibrating Analog Input Calibrating Analog Channels Calibrating RTDSetting the IOLAN’s Date and Time Rebooting the IolanResetting Calibration Data Resetting the Iolan to Factory Defaults Language SupportLoading a Supplied Language Software Upgrades and Language Files Translation GuidanceDownloading Terminal Definitions Creating Terminal Definition FilesResetting Configuration Parameters For exampleLost Admin Password 184 Iolan DS1/TS2 User’s Guide, Version Commands Virtual Modem Initialization CommandsAT&Sn AT&RnAT&Cn Pinouts and Cabling Diagrams Serial PinoutsDB25 Male DB25 Female RJ45 GND CTSDB9 Male Serial Only DB9 Male I/ODB25 Male EIA-232 Cabling DiagramsTerminal DB25 Connector DB25 FemaleRJ45 DB9 Male10-pin Pin Modem DB25 Connector Iolan RJ45 DCERxD TxD DTR 20 DTR GND Setting Jumpers Port IolanIolan DB25 Male/Female Iolan RJ45 DIP Digital I/O Module Analog Input Module 200 Iolan DS1/TS2 User’s Guide, Version Digital Input Wet Contact Wiring I/O DiagramsDigital I/O Digital Input Dry ContactDigital Output Sink Digital Output SourceCurrent Temperature InputAnalog Input VoltageRTD 4-Wire RTD 2-WireRTD 3-Wire Relay OutputNormally Closed Contact 206 Iolan DS1/TS2 User’s Guide, Version TruePort Utility TruePortAPI I/O Access Over TruePort API Request FormatAPI Response Format Error Codes 210 Iolan DS1/TS2 User’s Guide, Version Accessories Starter Kit Adapters/CableRJ45F to DB25M DTE Crossover Adapter RJ45F DB25M DTERJ45F to DB25M DCE Modem Adapter RJ45F to DB25F DTE Crossover Adapter RJ45F DB25FRJ45F to DB9M DTE Crossover Adapter Sun/Cisco RJ45M Connector Cable for Rack Mount Models RJ45F to DB9F DTE Crossover AdapterCommunication Issues TroubleshootingHardware Problems Power/Ready LED continues to flash green in Desktop modelsDeviceManager Problems Host ProblemsLogin Problems Problems with Terminals Unknown IP AddressLong Reboot Cycle DHCP/BOOTP ProblemsLanguage Problems ModelsGlossary Authentication Dial Users Services Reverse Connection PAP PasswordAuthentication Protocol Radius Remote RIP RoutingBootp IndexSnmp
Related manuals
Manual 246 pages 24.21 Kb Manual 88 pages 61.31 Kb Manual 122 pages 55.83 Kb

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.