Perle Systems TS2, DS1 manual Inactive Signal, Width

Page 144

Channels

Field Descriptions

Configure the following parameters:

Description

Provide a description of the channel, making it easier to identify.

 

Data Options: Maximum 20 characters, including spaces

Output

Specify how the channel output will be handled.

 

Data Options:

 

z Manual—You must manually manipulate the channel output.

 

z Pulse—Activates and deactivates the channel output activity in intervals

 

after it is manually activated.

 

z Inactive-to-ActiveDelay—The channel output will remain inactive for

 

the specified time interval after it is manually started.

 

z Active-to-InactiveDelay—The channel output will go inactive after the

 

specified time interval after it is manually started.

 

Default: Manual

Pulse Mode

When Output is set to Pulse, you can specify the manner of the pulse.

 

Data Options:

 

z Continuous—Continuously pulses active and inactive.

 

z Count—Pulses an active/inactive sequence for the specified number of

 

times.

 

Default: Continuous

Pulse Count

The channel output will pulse for the specified number of times; each count

 

consists of an active/inactive sequence.

 

Default: 1

Inactive Signal

How long the channel will remain inactive during pulse mode.

Width

Range: 1-9999 x 100 ms

 

Default: 1 (100 ms)

144

IOLAN DS1/TS2 User’s Guide, Version 3.4

Image 144
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents Configuration Methods DHCP/BOOTP Getting Started Configuring Serial Ports Console Management Profile Configuring Users Configuring Security UDP Configuring the System Controlling the I/O Channels Appendix a Virtual Modem AT Commands Appendix D I/O Wiring Diagrams Appendix G Troubleshooting Preface About This BookIntended Audience DocumentationTypeface Conventions Online HelpIntroduction About the IolanIolan Family Models Iolan Features HardwareSoftware SecurityIolan Features Connectivity IntroductionIolan Components Power Supply Specifications Getting to Know Your IolanDesktop Models OverviewDS1 Serial ActivityTop View End ViewConsole/Serial Switch Console ModeSerial Mode Powering Up the Iolan Serial Only ModelsModels Configuration Methods Chapter Configuration Methods Overview Configures an IP AddressRequires a Configured IP Address Easy Config Wizard Access Platforms Unique FeaturesConnecting to the Iolan Using DeviceManager DeviceManagerDeviceManager Using DeviceManager Connecting to the Iolan Using WebManager WebManagerUsing WebManager Command Line Interface Connecting to the Iolan Using the CLIThrough the Network Using the CLI Connecting to the Iolan Using the MenuMenu Through the Serial PortUsing the Menu Connecting to the Iolan Using DHCP/BOOTP Using DHCP/BOOTPDHCP/BOOTP Parameters Connecting to the Iolan Using Snmp SnmpUsing the Snmp MIB Snmp Easy Configuration Wizard Getting StartedSetting Up the Network Using a Direct Serial Connection to Specify an IP Address Using a Direct Serial Connection to Enable BOOTP/DHCPSet server internet dhcp/bootp on Using ARP-Ping For an IPv6 NetworkSetting Up the Serial Ports Setting Up the Serial Ports Setting Up Users Using DeviceManager WebManager Navigating DeviceManager/WebManager DeviceManagerWebManager Using DeviceManager to Connect to the Iolan Starting a New SessionAssigning a Temporary IP Address to a New Iolan Adding/Deleting Manual IOLANs Logging in to the IolanUsing WebManager to Connect to the Iolan Configuration FilesCreating a New Iolan Configuration in DeviceManager Logging into the IolanOpening an Existing Configuration File Importing an Existing Configuration FileManaging the Iolan Network Settings IP Settings IP SettingsOverview Field DescriptionsAutomatically server Default Enabled AdvancedAdvanced Host TableFunctionality Adding/Editing a Host Route ListAdding/Editing Routes Serial Ports FunctionalityEditing a Serial Port Resetting a Serial Port Serial Port Profiles Common TabsHardware Tab Field Descriptions Default None Default FullDefault Auto Flow Control Enable InboundPacket Forwarding Tab Field Descriptions Enable Trigger1 Enable Trigger2Packet Definition Packet SizeConsole Management Profile Default Telnet General Tab Field DescriptionsProtocol Listen for Connections on TCP Port Data Options IPv4 AddressAdvanced Tab Field Descriptions Dial Timeout Break HandlingDial Dial OutTruePort Profile System Default Enabled Host Name Connect to remoteTCP Port Connect toHost and backup Adding/Editing Additional TruePort HostsHosts to connect to Define a primaryBackup Host Adding/Editing a Multihost EntryPrimary Host Signals high Day Motd Default Disabled Idle TimeoutSession Timeout WhenTCP Sockets Profile General Tab Field Descriptions Adding/Editing Additional Hosts Adding/Editing a Multihost Entry Enable TCP KeepaliveUDP Sockets Profile This entry is disabled since Direction is set to Disabled Listen for connections on UDP port Direction Start IP AddressEnd IP Address AutolearnDefault 0 zero Terminal ProfileAny Port PortDefault Dumb VT100TVI925 VT320 specifically supporting VT320-7When any data is Day Motd Default DisabledProtocol AutomaticallyDisconnect User logs out Default Disabled Data RangeUser Service Settings Login SettingsTelnet Settings Interrupt QuitErase EchoSerial Tunneling Profile Serial Server TunnelSerial Client Iolan TunnelClient Default Disabled Host Name Act As TunnelServer Virtual Modem Profile 100 Iolan DS1/TS2 User’s Guide, Version DTR Signal Acts as RTS Signal Always On RTS Signal Acts as Phone Number to Host Mapping Control Signal I/O Profile VModem Phone Number EntryPhone Number Host IP AddressInput Signal Field Descriptions Invert SignalDescription LatchOutput Signal Field Descriptions Auto Clear ModeMode Default Disabled Syslog Manual ClearModbus Gateway Profile Settings Button Modbus/RTU ModeDestination Slave IP MappingsDefault 30 ms Default 1000 msAdvanced Field Descriptions Modbus Slave IP Settings Field Descriptions Adding/Editing Modbus Slave IP SettingsUID Start Default Host Default TCPUID End Data Options TCP or UDPModbus Slave Advanced Settings Field Descriptions Custom Application Profile General Tab Field DescriptionAdvanced Serial Settings Tab Closing Serial Port Default Disabled Deny MultipleNetwork MonitorModems Tab Adding/Editing a ModemName Name of the modem TruePort Baud Rate Tab Field Definitions116 Iolan DS1/TS2 User’s Guide, Version Configuring Users User Settings Adding/Editing Users General TabDefault Normal LevelServices Tab ServiceDefault DSPrompt Host IPDefault English Advanced TabLanguage Sessions Tab Session 1, 2, 3 ConnectSerial Port Access Tab 126 Iolan DS1/TS2 User’s Guide, Version Configuring Security ServicesField Descriptions Configuring I/O InterfacesChapter Settings Access FunctionalityAdvanced Slave Modbus Settings Failsafe Timer Functionality TimeoutDefault 30 seconds Failsafe Action is triggeredEnable UDP Broadcast of I/O Default Disabled StatusUDP Functionality Temperature Functionality UDP SettingsDefault Celsius UDP EntryChannels AnalogDefault Current Alarm SettingsDigital Input Digital I/OInput Mode 139 Digital Output Output Mode Default SinkDefault Manual OutputPulse Mode Inactive Signal Width Active Signal WidthDelay Pulse CountRelay Relay I/OMonitoring Device Server Application Industrial FreezersInactive Signal WidthActive Signal Temperature Default RTD Alarm Settings Basic Analog Alarm SettingsAdvanced Analog Alarm Settings Clear ModeTrigger Type ClearUDP Unicast Format Analog DataTotal Data Length Exists Serial Pin Signal Data UDP Unicast ExampleDigital/Relay Data Length DataModbus Slave Modbus Serial Application Connected to the Serial PortModbus Serial Application Connected to the Network Modbus I/O Access Modbus TCP ApplicationFunction Codes Coil/Register Descriptions Serial Port Coil/Register Descriptions A4/T4 RegistersData Model A1/T1 A2/T2 A3/T3 A4/T4 Holding Registers Input RegistersA4D2/A4R2 Registers Data Model D1/R1 D2/R2 CoilsSerial Pin Signals D4/D2R2 RegistersData Model D3/R1 D4/R2 Coils Data Model Pin CoilsModbus Serial Application TruePort Power Digital Output TruePort I/OTruePort/Modbus Combination PC running aPower Digital Output API Over TruePort OnlyPC running Custom Application API TruePort Accessing I/O Data Via TruePort SetupIntroduction Format of API Commands Get CommandsCommand Format Response FormatSet Commands Successful Response Format Unsuccessful Response FormatExample 1 Turn on the first relay on a D2R2 unit Example 2 Turn on the first and second relay on a D2R2 unitError Codes Snmp TrapsConfiguring the System Chapter AlertsSyslog Management Custom App/Plugin Login Tab Field Descriptions Field DescriptionBootup Files Tab Field Descriptions Message of the Day Motd Tab Field Descriptions Tftp Tab Field DescriptionsControlling the I/O Channels Activate Output Manually activates the channel output System Administration Chapter Managing Configuration FilesSaving Configuration Files Downloading Configuration FilesDownloading Configuration Files to Multiple IOLANs Reboot ServerServer Name Uploading Configuration Files Downloading Iolan FirmwareCalibrating Temperature Input Calibrating I/OCalibrating Analog Input Calibrating Analog Channels Calibrating RTDSetting the IOLAN’s Date and Time Rebooting the IolanResetting Calibration Data Resetting the Iolan to Factory Defaults Language SupportLoading a Supplied Language Software Upgrades and Language Files Translation GuidanceDownloading Terminal Definitions Creating Terminal Definition FilesResetting Configuration Parameters For exampleLost Admin Password 184 Iolan DS1/TS2 User’s Guide, Version Commands Virtual Modem Initialization CommandsAT&Sn AT&RnAT&Cn Pinouts and Cabling Diagrams Serial PinoutsDB25 Male DB25 Female RJ45 GND CTSDB9 Male Serial Only DB9 Male I/OEIA-232 Cabling Diagrams Terminal DB25 ConnectorDB25 Male DB25 FemaleRJ45 DB9 Male10-pin Pin Modem DB25 Connector Iolan RJ45 DCERxD TxD DTR 20 DTR GND Setting Jumpers Port IolanIolan DB25 Male/Female Iolan RJ45 DIP Digital I/O Module Analog Input Module 200 Iolan DS1/TS2 User’s Guide, Version Wiring I/O Diagrams Digital I/ODigital Input Wet Contact Digital Input Dry ContactDigital Output Sink Digital Output SourceTemperature Input Analog InputCurrent VoltageRTD 2-Wire RTD 3-WireRTD 4-Wire Relay OutputNormally Closed Contact 206 Iolan DS1/TS2 User’s Guide, Version TruePort Utility TruePortAPI I/O Access Over TruePort API Request FormatAPI Response Format Error Codes 210 Iolan DS1/TS2 User’s Guide, Version Accessories Starter Kit Adapters/CableRJ45F to DB25M DTE Crossover Adapter RJ45F DB25M DTERJ45F to DB25M DCE Modem Adapter RJ45F to DB25F DTE Crossover Adapter RJ45F DB25FRJ45F to DB9M DTE Crossover Adapter Sun/Cisco RJ45M Connector Cable for Rack Mount Models RJ45F to DB9F DTE Crossover AdapterTroubleshooting Hardware ProblemsCommunication Issues Power/Ready LED continues to flash green in Desktop modelsDeviceManager Problems Host ProblemsLogin Problems Problems with Terminals Unknown IP AddressDHCP/BOOTP Problems Language ProblemsLong Reboot Cycle ModelsGlossary PAP Password Authentication Protocol Radius RemoteAuthentication Dial Users Services Reverse Connection RIP RoutingBootp IndexSnmp
Related manuals
Manual 246 pages 24.21 Kb Manual 88 pages 61.31 Kb Manual 122 pages 55.83 Kb

DS1, TS2 specifications

Perle Systems TS2 and DS1 are advanced serial-to-Ethernet devices designed to facilitate seamless integration of serial devices with modern IP networks. These devices serve as crucial tools for businesses looking to enhance their communication capabilities while leveraging existing infrastructure.

One of the standout features of the Perle TS2 and DS1 is their ability to support multiple serial protocols including RS232, RS422, and RS485. This versatile support allows businesses to connect various legacy devices to their networks, ensuring that critical equipment can still communicate effectively in an increasingly digital landscape.

The TS2 model is particularly noted for its dual serial ports, enabling simultaneous communication with multiple devices. This capability is invaluable for applications requiring real-time data transmission, such as remote monitoring and automated control systems. The DS1 model, on the other hand, is designed for single-port use, making it an ideal solution for smaller-scale operations or specific single-device connections.

Both the TS2 and DS1 incorporate advanced features such as configuration through a web interface, which simplifies setup and management. Users can easily access device settings and monitor performance metrics remotely, enhancing operational efficiency. These devices also support various network protocols such as TCP/IP, UDP, and ICMP, ensuring compatibility with a wide range of network architectures.

In terms of security, Perle Systems prioritize user data protection. The TS2 and DS1 offer features including SSL encryption and SSH protection, providing an added layer of security for sensitive information transmitted over the network. This is particularly important for industries where data integrity and security are paramount, such as healthcare and finance.

Additionally, the rugged design of both devices ensures reliable performance even in harsh environments. With extended temperature ratings and robust housing, the TS2 and DS1 can operate in diverse conditions without compromising functionality.

To summarize, the Perle Systems TS2 and DS1 provide a reliable and flexible solution for connecting legacy serial devices to modern networks. With their support for multiple serial protocols, web-based management, robust security features, and rugged design, these devices cater to a variety of industries looking to modernize their communication infrastructure while maintaining existing equipment. Whether for large-scale operations or smaller implementations, the TS2 and DS1 equip businesses with the tools needed for effective serial communication in an IP-driven world.