Perle Systems CM-110-XXXXX, C-110-XXXXX Perle 10/100 Media Converter Module Installation Guide

Page 7

fiber link on either the transmit or receive line will be passed through to the local copper connection thus notifying the connected device.

If the Media Converter has been set to Link Pass-Through mode, the effect will be the same as FEF, since the link loss on the fiber receiver will result in bringing down the copper link, which will in turn cause the transmit fiber link to be brought down.

Note: If it is required to either generate or detect the FEF signal, then the FEF switch needs to be set.

Disabled: The Media Converter Module will not monitor for or generate Far End Fault.

The following diagram is an illustration of the operation of this feature.

(A)– Remote Media Converter setup for Far End Fault Enabled, Auto Negotiation – OFF and Link Mode – Standard.

(B)– Local Media Converter setup for Far End Fault - Enabled, Link Pass-Through - On and Auto Negotiation - OFF

1 – (A) Loses fiber connection on its receiver.

2 – (A) Sends FEF.

3 – (B) Detects FEF signal and shuts down the fiber link.

4 – (B) Drops link on copper connection because Link Pass-Through is configured.

5 – (A) Link on copper connection is not affected because Link Mode is set to Standard.

Perle 10/100 Media Converter Module – Installation Guide 7

Image 7
Contents CM-110-XXXXX Overview Auto-MDIX Jumper InstallationAuto-Config Jumper CM-110 only Auto Negotiation Switch Switch Position Mode DIP Switches DIP Switch SettingsFar End Fault Switch Switch Position Mode Link Mode Switch Switch PositionPerle 10/100 Media Converter Module Installation Guide Speed copper Switch Switch Position Mode Duplex copper Switch Switch Position ModeLoopback Switch Duplex fiber Switch Switch Position ModeInstalling or Replacing a Media Converter Module Installing or Replacing Media Converter ModulesInstalling the Duplex Fiber Cable Installing the Copper Cable Status LED OperationAuto-MDIX Error RecoveryPause Ieee 802.3xy Method TroubleshootingGeneral No connectivityMethod Technical Specifications Ethernet Copper Cabling Requirements Fiber Cabling RequirementsCompliance Information EN 55022, Class a EN 55024, Class a Laser Safety IECContacting Technical Support Warranty / RegistrationCopyright