Installing or Replacing Media Converter Modules

Caution: Observe electrostatic discharge precautions when installing the Media Converter Module(s) into the Chassis. Failure to observe this caution could result in damage to the Media Converter Module(s) and /or chassis.

The Perle Media Converter Modules can be installed in any available slot and in any order within the Chassis.

Installing or Replacing a Media Converter Module

1.Remove the Media Converter Module from its packaging.

2.Using a cross-head screwdriver, remove the screw holding the face plate to the Chassis to reveal the slot opening.

3.Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode.

4.Locate the top and bottom alignment guides inside the Chassis.

5.Using the module alignment guides gently slide the module into the slot until it becomes flush with the front of the Chassis. Light pressure may be needed to seat the module. Do not force the module as you might cause some damage. If there is resistance, remove the module, check the module connector for damaged or incorrectly aligned pins, if there is no damage, retry module insertion.

10

Perle 10/100 Media Converter Module – Installation Guide

Image 10
Contents CM-110-XXXXX Overview Installation Auto-MDIX JumperAuto-Config Jumper CM-110 only DIP Switches DIP Switch Settings Auto Negotiation Switch Switch Position ModeLink Mode Switch Switch Position Far End Fault Switch Switch Position ModePerle 10/100 Media Converter Module Installation Guide Duplex copper Switch Switch Position Mode Speed copper Switch Switch Position ModeDuplex fiber Switch Switch Position Mode Loopback SwitchInstalling or Replacing Media Converter Modules Installing or Replacing a Media Converter ModuleInstalling the Duplex Fiber Cable Installing the Copper Cable Operation Status LEDAuto-MDIX Error RecoveryPause Ieee 802.3xy No connectivity TroubleshootingGeneral MethodMethod Technical Specifications Fiber Cabling Requirements Ethernet Copper Cabling RequirementsEN 55022, Class a EN 55024, Class a Laser Safety IEC Compliance InformationContacting Technical Support Warranty / RegistrationCopyright