2.2 I/O Base Address Setting

The OME-A-8111 occupies 16 consecutive locations in I/O address space. The base address is set by DIP switch SW1. The default address is 0x220 as shown below:

A9

A8

A7

A6

A5

A4

ON

 

1

2

3

4

5

6

 

 

 

SW1 : BASE ADDRESS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BASE ADDR

 

A9

A8

 

A7

 

A6

A5

 

A4

200-20F

 

OFF

ON

 

ON

 

ON

ON

 

ON

210-21F

 

OFF

ON

 

ON

 

ON

ON

 

OFF

220-22F(;)

 

OFF

ON

 

ON

 

ON

OFF

 

ON

230-23F

 

OFF

ON

 

ON

 

ON

OFF

 

OFF

:

 

:

:

 

:

 

:

:

 

:

300-30F

 

OFF

OFF

 

ON

 

ON

ON

 

ON

:

 

:

:

 

:

 

:

:

 

:

3F0-3FF

 

OFF

OFF

 

OFF

 

OFF

OFF

 

 

(;): default base address is 0x220

OME-A-8111 Hardware Manual (ver.1.1, Jul/2003)

9

Image 11
Contents User’sGuide Czech Republic CanadaMexico BeneluxOME-A-8111 Table of Contents Calibration General Description Features3 A/D Converter SpecificationsPower Consumption Analog Inputs Interrupt Channel DA Converter Digital I/O Applications Programmable Timer/CounterProduct Check List Board Layout Hardware ConfigurationDefault base address is I/O Base Address Setting1 JP1 D/A Internal Reference Voltage Selection Jumper SettingAddress Read Write I/O Register Address2 A/D Input Buffer Register 8254 Counter4 D/I Input Buffer Register 3 D/A Output Latch Register6 A/D Gain Control Register Clear Interrupt Request7 A/D Multiplex Control Register SI2 SI1 SI0 8 A/D Mode Control Register9 A/D Software Trigger Control Register 10 D/O Output Latch Register CN3 Digital I/OCounter 8254 Timer/CounterSec A/D Conversion2 A/D Conversion Trigger Modes If switching from one channel to the next secPacer Trigger Mode 1 A/D conversion flow3 A/D Transfer Modes Using software trigger and polling transferD/A Conversion Signal Shielding Analog Input Signal ConnectionCN1 Analog input/Analog output/Connect Pin Assignment Pin AssignmentCN3 Analog input/Analog output/Connect Pin Assignment CN2 Analog input/Analog output/Connect Pin AssignmentOME-DB-16R Daughter BoardOME-CA-4002 OME-DB-16PCalibration VR Description CalibrationA/D Calibration Steps DI/O TestingD/A Calibration Steps WARRANTY/DISCLAIMER Temperature