Omron C-series manual Optical Fiber Cable APF/PCF

Page 18

 

Optical Fiber Cable (APF/PCF)

Section 2-3

Soldering

Observe the following when soldering wires onto the connector.

1, 2, 3... 1. Place heat-shrink tubing onto all wires far enough from the end so as to not interfere with soldering.

2.Pre-solder all wires and connector terminals.

3.Solder all wires, inserting 4 mm of the exposed 5 mm of wire into the connec- tor terminal.

4.Slide the heat-shrink tubing onto the soldered area and shrink into place.

Hood Assembly

Assemble the connector hood as shown in the following diagram.

Boot

Aluminum foil tape

2-3 Optical Fiber Cable (APF/PCF)

Although the special characteristics of optical fiber call for care in connecting op- tical devices, laying optical fiber cables basically does not differ from laying wire cables. All OMRON PCF and the PF10l APF (length: 1 m) cables come with con- nectors attached. Connectors for all other APF cables must be assembled by the customer. Note the following precautions when handling optical fiber cables:

1, 2, 3... 1. Always turn the power off to the Link Adapter when connecting or discon- necting an optical fiber cable.

2.Always hold the connector when disconnecting an optical fiber cable; never pull on the cable.

3.APF and PCF connectors are designed to be inserted only in one direction; do not try to force them in the wrong way.

4.Insert APF and PCF connectors until they lock into position.

5.Always place the protective caps on unused Link Adapter modules.

6.If dirty, clean connectors gently with a tissue or sanitary cotton, using ethyl alcohol if necessary. Do not use any solvent other than ethyl alcohol.

8

Image 18
Contents Series Link Adapters Sysmac C-series Link Adapters Page Omron Product References Page Table of Contents Precautions General Precautions Safety PrecautionsIntended Audience Operating Environment Precautions Application PrecautionsXii Section IntroductionNomenclature Link AdaptersGeneral Specifications Repeater UnitsLink Adapters Repeater Units Wiring and Power Supply RS-422 and RS-232C Cable Power Supply and Cable LengthsPower Supply Cable LengthsConnecting Link Adapter AL004-PE SectionOptical Fiber Cable APF/PCF Specifications Crystal Optical Fiber Cable AGFBackup Power Supply Using the Auxiliary Power Input TerminalExample Section Link Adapter Repeater Input Repeater Units Nomenclature and Indicator Lights Connections Dimensions System Configuration PC Link Systems Host Link Systems AL004-PE as shown belowOptical Remote I/O Systems UnitsLow Cable LengthWired Remote I/O Systems Dimensions and Internal Configuration Link Adapter AL001 Link Adapter AL002-PE Link Adapter AL004-PE CTS SelectorTermination Resistance Link Adapter AL005-PE Link Adapter AL006-PE Link Adapter AL007-P Appendix a Standard ModelsWire Cable Index Revision History Authorized Distributor