Omron C-series manual Link Adapter Repeater Input

Page 22

Link Adapter Repeater Input

Section 2-6

2-6 Link Adapter Repeater Input

Link Adapters AL002-(P)E and AL006-(P)E have repeater input terminals. They are used when it is necessary to be sure that power has already been turned on in a system connected to a branch line of the Link Adapter before signals are transmitted along the main line. They should be kept connected (ON) when not needed. When they are connected across, signals are relayed along the Link Adapter's main line. Once main line transmission has started, signals will contin- ue to be relayed even if the repeater input terminals are opened (OFF).

Link Adapter

Main line

Link Adapter AL002-(P)E or AL006-(P)E

Relay input

Branch line

Main line

Link Adapter

Master

Branch system

Terminator

Units which may be connected to a branch line (as is branch system above)

Units with repeat input terminals (I/O Link Units)

Branch

To the repeater input

 

line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeater output

Connect the Link Adapter's repeat input to the I/O Link Unit's repeater output.

Units without repeater input terminals (Units other than I/O Link Units)

X

Branch line

Relay

X

Power source

Connect so that the repeater input sill be ON when power is turned on in the Unit connected to the branch line (in this case a Remote I/O Slave).

If the repeater input is connected across directly (not used) in the above exam- ple, control system operation will begin when the Master detects the terminator, even if power to the branch system is off. In other words, the branch system is ignored. The repeater input is used to prevent this from happening. When the repeater input is connected as shown above, then the Link Adapter's main line will not transmit data as long as power is not turned on in the branch system, thereby preventing the entire system from starting. Once the branch system is operating normally, however, signals will continue to be transmitted along the main line even if the repeater input turns OFF.

12

Image 22
Contents Series Link Adapters Sysmac C-series Link Adapters Page Omron Product References Page Table of Contents Precautions Safety Precautions General PrecautionsIntended Audience Operating Environment Precautions Application PrecautionsXii Section IntroductionNomenclature Link AdaptersRepeater Units General SpecificationsLink Adapters Repeater Units Wiring and Power Supply RS-422 and RS-232C Cable Power Supply and Cable LengthsPower Supply Cable LengthsConnecting Link Adapter AL004-PE SectionOptical Fiber Cable APF/PCF Specifications Crystal Optical Fiber Cable AGFUsing the Auxiliary Power Input Terminal Backup Power SupplyExample Section Link Adapter Repeater Input Repeater Units Nomenclature and Indicator Lights Connections Dimensions System Configuration PC Link Systems Host Link Systems AL004-PE as shown belowOptical Remote I/O Systems UnitsLow Cable LengthWired Remote I/O Systems Dimensions and Internal Configuration Link Adapter AL001 Link Adapter AL002-PE CTS Selector Link Adapter AL004-PETermination Resistance Link Adapter AL005-PE Link Adapter AL006-PE Link Adapter AL007-P Appendix a Standard ModelsWire Cable Index Revision History Authorized Distributor