Omron C-series manual Host Link Systems, AL004-PE as shown below

Page 28

Host Link SystemsSection 4-2

4-2

Host Link Systems

 

 

Link Adapters are used in Host Link Systems for branching and for converting to

 

 

the type of cable required by the host computer.

Example 1

A Wired Host Link System can be connected using Link Adapters AL004-(P)E

 

 

and AL001 as shown below. Link Adapter AL004-(P)E is used to convert be-

 

 

tween RS-232C and RS-422 cable. Link Adapter AL001 is used for branching.

Host computer

RS-232C(15 m max.)

Link Adapter

AL004-(P)E

 

RS-422

 

 

 

 

 

 

 

RS-422

 

 

RS-422

 

Link Adapter

Link Adapter

 

 

 

 

AL001

 

AL001

 

 

 

 

 

 

 

 

 

 

RS-422 branch line

 

RS-422 branch line

 

(10 m max.)

 

(10 m max.)

 

 

 

 

 

 

 

CPU Rack with

 

CPU Rack with

 

 

Host Link Unit

 

Host Link Unit

 

 

 

 

 

 

 

 

 

Link Adapter

RS-422

 

 

 

 

 

AL001

 

 

 

 

 

 

 

 

 

RS-422 branch line

 

 

 

(10 m max.)

 

 

 

 

 

 

 

CPU Rack with

 

CPU Rack with

Host Link Unit

 

Host Link Unit

 

 

 

 

 

Example 2

Optical Host Link Systems can be connected in series using Link Adapter

 

AL004-(P)E as shown below.

 

 

Host computer

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-422 or RS-232C

 

 

 

 

 

 

 

 

 

Link Adapter

 

 

 

 

AL004-(P)E

 

 

 

 

 

 

 

Optical fiber (APF/PCF)

 

 

 

 

 

 

 

 

 

Optical fiber (APF/PCF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C-Series PC

 

C-Series PC

 

C-Series PC

 

C-Series PC

with

 

with

 

with

 

with

Optical Host

 

Optical Host

 

Optical Host

 

Optical Host

Link Unit

 

Link Unit

 

Link Unit

 

Link Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C-Series PC

with

Optical Host

Link Unit

19

Image 28
Contents Series Link Adapters Sysmac C-series Link Adapters Page Omron Product References Page Table of Contents Precautions Safety Precautions General PrecautionsIntended Audience Operating Environment Precautions Application PrecautionsXii Section IntroductionNomenclature Link AdaptersRepeater Units General SpecificationsLink Adapters Repeater Units Wiring and Power Supply Power Supply and Cable Lengths Power SupplyRS-422 and RS-232C Cable Cable LengthsConnecting Link Adapter AL004-PE SectionOptical Fiber Cable APF/PCF Specifications Crystal Optical Fiber Cable AGFUsing the Auxiliary Power Input Terminal Backup Power SupplyExample Section Link Adapter Repeater Input Repeater Units Nomenclature and Indicator Lights Connections Dimensions System Configuration PC Link Systems Host Link Systems AL004-PE as shown belowOptical Remote I/O Systems UnitsLow Cable LengthWired Remote I/O Systems Dimensions and Internal Configuration Link Adapter AL001 Link Adapter AL002-PE CTS Selector Link Adapter AL004-PETermination Resistance Link Adapter AL005-PE Link Adapter AL006-PE Link Adapter AL007-P Appendix a Standard ModelsWire Cable Index Revision History Authorized Distributor