Figure 3-4. System Information.
5.The login name is “admin”. And there is no password assigned. We strongly recommend you enable password for admin access to secure access to the switch management function. After successful login, the screen should show (FSM7352S)> prompt. Enter “show sysinfo”, and it will display the management CPU’s IP address. The switch is shipped with DHCP as default to receive its IP address, to manually set a static IP address, you must first disable DHCP as follows:
(FSM7352S) > en Password: <just hit enter> (FSM7352S)# network protocol none
Changing protocol mode will reset ip configuration. Are you sure you want to continue? (y/n)y
After system prompt return, enter the following command
(FSM7352S) # network parms 192.168.1.100 255.255.255.0 192.168.1.1
The example above uses “192.168.1.100” as IP address, and “192.168.1.1” as gateway IP address. The gateway address is optional.You should provide your own IP address in the above command.
If you want to use your web browser, or telnet session to manage your switch, note the IP address on the
Page 17 of 24