NETGEAR manual FSM7352S # network parms 192.168.1.100 255.255.255.0, System Information

Page 17

Figure 3-4. System Information.

5.The login name is “admin”. And there is no password assigned. We strongly recommend you enable password for admin access to secure access to the switch management function. After successful login, the screen should show (FSM7352S)> prompt. Enter “show sysinfo”, and it will display the management CPU’s IP address. The switch is shipped with DHCP as default to receive its IP address, to manually set a static IP address, you must first disable DHCP as follows:

(FSM7352S) > en Password: <just hit enter> (FSM7352S)# network protocol none

Changing protocol mode will reset ip configuration. Are you sure you want to continue? (y/n)y

After system prompt return, enter the following command

(FSM7352S) # network parms 192.168.1.100 255.255.255.0 192.168.1.1

The example above uses “192.168.1.100” as IP address, and “192.168.1.1” as gateway IP address. The gateway address is optional.You should provide your own IP address in the above command.

If you want to use your web browser, or telnet session to manage your switch, note the IP address on the

Page 17 of 24

Image 17
Contents Trademarks Internet/World Wide Web Contents Figures Overview IntroductionFeatures Shows the package contents for the Managed Switch Package ContentsCD ROM Verify that your package contains the following10/100/1000 Mbps RJ-45 Ports Physical DescriptionFront and Back Panels SFP module bay Label Description LED DescriptionsConsole Port Page Preparing the Site InstallationCharacteristics Requirements Checking the Installation Installing the SwitchApplying AC Power Installing the Switch on a Flat SurfaceInstalling a SFP Module Connecting Devices to the SwitchInstalling a Gigabit Ethernet fiber Module into an FSM7352S System Information FSM7352S # network parms 192.168.1.100 255.255.255.0Connecting the stacking modules Layer 2 Services Appendix a Technical SpecificationsLayer 3 Services Switch ManagementPhysical Dimensions Power SupplyEnvironmental Specifications InterfaceSafety Troubleshooting Chart Appendix B TroubleshootingAdditional Troubleshooting Suggestions Table B-1. Troubleshooting Chart Symptom Cause SolutionAuto Negotiation ConfigurationSwitch Integrity Appendix C Default Settings