Milan Technology EFLHB0X00, E-FL-HB-0400 Technical Specifications, Declaration of Conformity

Page 2

E-FL-HB-0x00 IN THE NETWORK

TECHNICAL SPECIFICATIONS

Install one E-FL-HB-0x00 hub and use fiber cable to set up a workgroup by connecting the hub to terminal devices.

10BASE-FL

1

2

3

4

5

6

7

8

Standards

IEEE 802.3

 

Dimensions

17.25" x 8.5" x 1.7"

(437 mm x 216 mm x 43 mm)

Power

 

 

Input Range:

100 to 240 VAC at 50 or 60 Hz, 3.0 A maximum.

 

Rated at 40 watts maximum.

Environment

Operating Temperature:

0° to 50°C (32° to 122° F )

 

Storage Temperature:

-15° to 65°C (5° to 149° F )

 

Humidity

5% to 95%, non condensing

 

Altitude

0 to 10,000 feet

Warranty

Lifetime

 

 

 

to hub, switch, or router

Install an optional backbone

 

 

 

 

 

 

 

 

uplink adaptor at the back of

 

 

 

 

 

 

 

 

the hub and use 10BASE-2,

 

 

 

 

 

 

 

 

10BASE-5, or fiber cable to

 

 

 

 

 

 

 

 

connect the workgroup to a

 

 

 

 

 

 

 

 

network backbone.

10BASE-FL

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

Cascade two repeater hubs by connecting fiber cable from a connector

 

 

DECLARATION OF CONFORMITY

 

 

 

 

 

 

 

Name of Mfg:

Transition Networks

 

6475 City West Parkway, Minneapolis MN 55344 USA

at the front of the first hub to a connector at the front of the second hub.

to hub, switch or router

Model:E-FL-HB-0x00 Series Unmanaged Fiber Hub

Part Number: E-FL-HB-0800, E-FL-HB-0800(SC), E-FL-HB-0400,

E-FL-HB-0400(SC)

Regulation: EMC Directive 89/336/EEC

Purpose: To declare that the E-FL-HB-0800or E-FL-HB-0400to which this declaration refers is in conformity with the following standards.

10BASE-FL

 

 

 

 

 

 

 

10BASE-FL

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

 

 

 

_November 10, 1999_____

 

Stephen Anderson, Vice-President of Engineering

Date

 

 

 

 

Image 2
Contents FL-HB-0400, E-FL-HB-0400SC Compliance InformationFL-HB-0800, E-FL-HB-0800SC Technical Specifications Declaration of ConformityAUI/10BASE-5 Cable Specifications Cable Specifications10BASE-2 Cable Specifications 10BASE-FL Cable SpecificationsYES InstallationOptionally Install Backbone Uplink Adapter Is one or more of the 10BASE-FL ACTivity LEDs illuminated?Is the BackBone STATus LED illuminated continuously? Install E-FL-HB-0x00 at SiteIs the PoWeR LED on the E-FL-HB-0x00 illuminated? Does the BackBone STATus LED continuously blink ONCE?Optionally Connect to Backplane 10BASE-FL IndicatorsOperation Through AUI UplinkTo connect to 10BASE-2 network Power the E-FL-HB-0x00Through BNC Uplink Optionally Cascade E-FL-0x00 Hubs Connect E-FL-0x00 Hub to Terminal Devices using FiberTo cascade hubs by installing fiber cables between hubs Through Fiber Uplink