Milan Technology EFLHB0X00 Operation, Optionally Connect to Backplane, Through AUI Uplink

Page 6

Optionally Connect to Backplane

THROUGH AUI UPLINK

NOTE: Refer to 5-4-3 rule (page 3) to keep network configuration within acceptable bounds.

50

Terminator

Earth Ground

50Terminator

USING TRANSCEIVER

NOTE: Refer to transceiver documentation for detailed specifications and instructions.

1.Locate AUI uplink adapter installed at E-FL-HB-0x00 back. (See page 4.)

2.Locate IEEE 802.3 compliant transceiver with male AUI connector and with required network media connector.

3.Connect transceiver male AUI connector to the female AUI connector on E-FL-HB-0x00

4.Referring to transceiver documentation, connect transceiver network media connector to the network media.

USING DROP CABLE

NOTE: In a coax thicknet installation, each 10BASE-5 cable end must be terminated using a 50 ohm terminator. Additionally, the 10BASE-5 segment must be grounded to “earth ground” at one end.

1.Locate AUI uplink adapter installed at E-FL-HB-0x00 back. (See page 4.)

2.Locate or build IEEE 802.3 compliant AUI drop cable. (See page 14.)

3.Connect AUI drop cable male connector to female AUI (DTE) connector on E-FL-HB-0x00

OPERATION

Use the status LEDs to monitor E-FL-HB-0x00 operation in the network.

BB

 

 

 

10BASE-FL

 

 

 

 

 

 

 

 

 

 

 

PWR

STAT

 

 

 

 

 

 

 

 

COL

ACT

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

E-FL-0X00 HUB INDICATORS

 

 

 

 

 

 

 

 

P(o)W(e)R

Steady LED indicates E-FL-HB-0x00 is

 

 

connected to external AC power.

 

COL(lision)

Flashing LED indicates network collisions.

B(ACK)B(ONE) INDICATORS

 

 

 

 

 

 

 

STAT(us)

Steady LED indicates, for network

 

 

 

connection, a valid link and no partition or

 

 

isolation.

 

 

 

 

 

 

 

One (1) continuous, flashing blink indicates

 

network link is down.

 

Two (2) continuous, flashing blinks indicate

 

reception of Far End Fault (if fiber uplink

 

adapter is installed and LINKAlert™ is

 

enabled) OR port is partitioned (if AUI or

 

BNC or fiber uplink adapter with

 

LINKAlert™ not enabled is installed).

ACT(ivity)

Flashing LED indicates reception of network

 

data packet(s).

10BASE-FL INDICATORS

 

STAT(us)

Steady LED indicates, for each port, a valid

 

link and no partition or isolation.

 

One (1) continuous, flashing blink indicates

 

link is down.

 

Two (2) continuous, flashing blinks indicate

 

port is partitioned.

ACT(ivity)

Flashing LED indicates, for each port,

 

reception of data packet(s).

Image 6
Contents Compliance Information FL-HB-0800, E-FL-HB-0800SCFL-HB-0400, E-FL-HB-0400SC Technical Specifications Declaration of ConformityAUI/10BASE-5 Cable Specifications Cable Specifications10BASE-2 Cable Specifications 10BASE-FL Cable SpecificationsYES InstallationOptionally Install Backbone Uplink Adapter Is one or more of the 10BASE-FL ACTivity LEDs illuminated?Is the BackBone STATus LED illuminated continuously? Install E-FL-HB-0x00 at SiteIs the PoWeR LED on the E-FL-HB-0x00 illuminated? Does the BackBone STATus LED continuously blink ONCE?Optionally Connect to Backplane 10BASE-FL IndicatorsOperation Through AUI UplinkPower the E-FL-HB-0x00 Through BNC UplinkTo connect to 10BASE-2 network Optionally Cascade E-FL-0x00 Hubs Connect E-FL-0x00 Hub to Terminal Devices using FiberTo cascade hubs by installing fiber cables between hubs Through Fiber Uplink