Milan Technology E-FL-HB-0400 10BASE-2 Cable Specifications, 10BASE-FL Cable Specifications

Page 3

CABLE SPECIFICATIONS

10BASE-2 Cable Specifications

10BASE-2 CABLE CHARACTERISTICS:

Cable type:

Stranded Coaxial RG58 (ThinNet)

Impedance:

50 @ 10 MHz

 

Mutual Capacitance:

24 pF/ft ±20% @ 10

MHz

Maximum Cable Length:

185 meters (610 feet)

Maximum number network connections:

30

 

Minimum distance between connections:

0.5 meters (1.6 feet)

 

Terminate 10BASE-2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground.

AUI/10BASE-5 Cable Specifications

10BASE-5 CABLE CHARACTERISTICS:

Cable type:

RG8 Solid Coaxial (ThickNet)

Impedance:

50 @ 10 MHz

Capacitance:

26pF/ft

Maximum Cable Length:

500 meters (1650 feet)

Maximum number network connections:

100

Minimum distance between connections:

2.5 meters (8.2 feet)

Terminate 10BASE-5 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground.

AUI CABLE AND CONNECTOR SPECIFICATIONS

E-FL-HB-0x00 in Half-Duplex Network

The 5-4-3 Rule applies separately to each collision domain. NOTE: A collision domain is any Carrier Sense Multiple Access with Collision Detection (CSMA/CD) network in which a collision will occur if two attached stations transmit at the same time. A segment is the cable connection between two network interfaces.

USING THE 5-4-3 RULE:

The 5-4-3 Rule allows no more than five segments in any 10-Mb/sec Ethernet collision domain, no more than four repeaters (hubs) and no more than three populated segments (10Base-2 or 10BASE-5 coaxial- cable installations).

To determine the size of the collision domain by assigning segment numbers to cable connections, determine the two network devices in a transmission path that are separated by the greatest number of segments. Define a segment path between the network devices by labeling the cable connection to the first device “segment 1” and numbering each segment in the path to the last network device, up to “segment n” (n = total number of segments 5). Verify that no segment path in the entire collision domain contains more than n 5 segments.

The cable is a special 4-pair individually shielded with an overall braided shield.

Maximum AUI Cable Length:

 

50 meters (165 feet)

 

AUI CONNECTOR CHARACTERISTICS:

 

 

 

AUI Port:

Male DB-15 with locking posts.

 

 

AUI Connection:

Cable shell must be grounded.

 

 

Connector Legend:

1

Logic Ref.

6

Power Return

11

Logic Ref

 

2

Collision+

7

N/C

12

Receive

 

3

Transmit+

8

Logic Ref.

13

Power

 

4

Logic Ref.

9

Collision--

14

Logic Ref.

 

5

Receive+

10

Transmit-

15

N/C

4

3

4

10BASE-FL Cable Specifications

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

3

 

 

 

 

 

 

 

 

 

 

Optional:

100 / 140 µm multimode fiber

 

 

 

 

 

 

 

 

 

 

 

 

85 / 125 µm multimode fiber

 

 

 

 

 

 

 

 

 

 

 

 

50 / 125 µm multimode fiber

 

 

 

 

 

 

 

 

 

 

 

Wavelength

1300 nM

 

 

 

 

 

 

 

 

 

 

 

 

Fiber Optic Transmitter Power:

min: -__._ dBm

max: -__._ dBm

 

 

 

 

 

 

 

 

 

 

 

Fiber Optic Receiver Sensitivity:

min: -__._ dBm

max: -__._ dBm

 

 

 

 

 

 

 

 

 

 

 

Typical Maximum Cable Distance*:

2000 meters (6600 feet)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Actual distance dependent upon physical characteristics of network installation.

2

4

3

5

4

 

1

Image 3
Contents Compliance Information FL-HB-0800, E-FL-HB-0800SCFL-HB-0400, E-FL-HB-0400SC Declaration of Conformity Technical Specifications10BASE-FL Cable Specifications Cable Specifications10BASE-2 Cable Specifications AUI/10BASE-5 Cable SpecificationsIs one or more of the 10BASE-FL ACTivity LEDs illuminated? InstallationOptionally Install Backbone Uplink Adapter YESDoes the BackBone STATus LED continuously blink ONCE? Install E-FL-HB-0x00 at SiteIs the PoWeR LED on the E-FL-HB-0x00 illuminated? Is the BackBone STATus LED illuminated continuously?Through AUI Uplink 10BASE-FL IndicatorsOperation Optionally Connect to BackplanePower the E-FL-HB-0x00 Through BNC UplinkTo connect to 10BASE-2 network Through Fiber Uplink Connect E-FL-0x00 Hub to Terminal Devices using FiberTo cascade hubs by installing fiber cables between hubs Optionally Cascade E-FL-0x00 Hubs