CABLE SPECIFICATIONS
10BASE-2 Cable Specifications
10BASE-2 CABLE CHARACTERISTICS:
Cable type: | Stranded Coaxial RG58 (ThinNet) | |
Impedance: | 50 Ω @ 10 MHz |
|
Mutual Capacitance: | 24 pF/ft ±20% @ 10 | MHz |
Maximum Cable Length: | 185 meters (610 feet) | |
Maximum number network connections: | 30 |
|
Minimum distance between connections: | 0.5 meters (1.6 feet) |
|
Terminate
AUI/10BASE-5 Cable Specifications
10BASE-5 CABLE CHARACTERISTICS:
Cable type: | RG8 Solid Coaxial (ThickNet) |
Impedance: | 50 Ω @ 10 MHz |
Capacitance: | 26pF/ft |
Maximum Cable Length: | 500 meters (1650 feet) |
Maximum number network connections: | 100 |
Minimum distance between connections: | 2.5 meters (8.2 feet) |
Terminate
AUI CABLE AND CONNECTOR SPECIFICATIONS
E-FL-HB-0x00 in Half-Duplex Network
The
USING THE 5-4-3 RULE:
The
To determine the size of the collision domain by assigning segment numbers to cable connections, determine the two network devices in a transmission path that are separated by the greatest number of segments. Define a segment path between the network devices by labeling the cable connection to the first device “segment 1” and numbering each segment in the path to the last network device, up to “segment n” (n = total number of segments ≤ 5). Verify that no segment path in the entire collision domain contains more than n ≤ 5 segments.
The cable is a special
Maximum AUI Cable Length: |
| 50 meters (165 feet) |
| |||
AUI CONNECTOR CHARACTERISTICS: |
|
|
| |||
AUI Port: | Male |
|
| |||
AUI Connection: | Cable shell must be grounded. |
|
| |||
Connector Legend: | 1 | Logic Ref. | 6 | Power Return | 11 | Logic Ref |
| 2 | Collision+ | 7 | N/C | 12 | Receive |
| 3 | Transmit+ | 8 | Logic Ref. | 13 | Power |
| 4 | Logic Ref. | 9 | 14 | Logic Ref. | |
| 5 | Receive+ | 10 | Transmit- | 15 | N/C |
4 |
3 | 4 |
10BASE-FL Cable Specifications
Fiber Optic Cable Recommended: | 62.5 / 125 µm multimode fiber | 3 |
|
|
|
|
|
|
|
|
|
| |
Optional: | 100 / 140 µm multimode fiber |
|
|
|
|
|
|
|
|
|
|
| |
| 85 / 125 µm multimode fiber |
|
|
|
|
|
|
|
|
|
|
| |
| 50 / 125 µm multimode fiber |
|
|
|
|
|
|
|
|
|
|
| |
Wavelength | 1300 nM |
|
|
|
|
|
|
|
|
|
|
|
|
Fiber Optic Transmitter Power: | min: | max: |
|
|
|
|
|
|
|
|
|
|
|
Fiber Optic Receiver Sensitivity: | min: | max: |
|
|
|
|
|
|
|
|
|
|
|
Typical Maximum Cable Distance*: | 2000 meters (6600 feet) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Actual distance dependent upon physical characteristics of network installation.
2
4 |
3
5 | 4 |
|
1