LSI SAS2 manual Select Create RAID 1 Volume, Create New Array window appears

Page 14

Chapter 3: Creating Mirrored Volumes Creating Mirrored Volumes

SAS2 Integrated RAID Solution User Guide

3.2.1Creating an Integrated Mirroring Volume

Disks must have 512-byte blocks and must not have removable media.

Integrated mirroring volumes must have two disks, Integrated Mirroring Enhanced volumes can have three-to-ten disks, and Integrated Mirroring + Striping volumes can have an even number of disks ranging from four-to-ten disks.

NOTE: LSI strongly recommends that you create global hot spare disks for all mirrored volumes to increase the level of data protection. If a disk in a mirrored volume fails, the Integrated RAID firmware rebuilds it using one of the global hot spares, and the data is safe. If you create two mirrored volumes on an LSI SAS 2 controller, either of the two mirrored volumes can use the global hot spares if a disk fails.

Follow these steps to create a two-disk Integrated Mirroring (RAID 1) volume with the SAS2 BIOS CU. The steps begin with the Adapter List window that appears when the SAS2 BIOS CU starts:

1.On the Adapter List window, use the arrow keys to select an LSI SAS adapter, and then press Enter.

The Adapter Properties window appears, as the following figure shows.

Figure 5: Adapter Properties Window

2.Use the arrow keys to select RAID Properties, and then press Enter. The Create Array window appears.

3.Select Create RAID 1 Volume.

The Create New Array window appears.

Page 14

LSI Corporation Confidential August 2010

Image 14
Contents SAS2 Integrated RAID Solution Revision History Table of Contents Table of Contents Overview Introduction to the Integrated RAID SolutionFeatures Enhanced RAID 1EBenefits and Features Types of mirrored arrays Overview of Integrated RAID Mirrored VolumesIntroduction Operation of Mirrored Volumes Typical Integrated Mirroring Implementation Integrated Mirroring Enhanced with Three Disks Mirrored Volume Features SAS2 Integrated RAID Solution User Guide Configuration Overview Creating Mirrored VolumesMirrored Volume Please wait, invoking SAS Configuration UtilitySelect Create RAID 1 Volume Create New Array window appearsSelect Create RAID 1E Volume Expanding an Integrated Mirroring Volume with OCE Array on this adapter Manage Array window appearsSelect New Array Type window appears Following figureHot Spare status changes to Yes Manage Hot Spares window appearsSmart support Press C to create the hot spare diskOther Configuration Tasks Press Enter Follow these steps to activate a selected volumeCurrently inactive Select RAID Properties, and then press EnterHighlight SAS Topology, and press Enter Follow these steps to select a boot diskSAS2 Bios CU, select an adapter from the Adapter List SAS Topology window appearsBoot Device on SAS Topology Window Overview of Integrated Striping Boot disk or as a data diskVolumes can consist of two-to-ten disks Integrated Striping Description Integrated Striping ExampleCreating Integrated Striping Volumes Creating Integrated Striping VolumesSelect Create RAID 0 Volume Viewing Volume Properties Activating an Array Select Delete Array Alternate device Following figure showsSAS2 Integrated RAID Solution User Guide Requirements Using the SAS2 Integrated RAID Configuration UtilityHardware and Software Interface Description Commands EFICommand to get the enclosure and slot numbers of a drive GB of capacity on the disk drive VolumeName a user-specified string to identify the volume Following fields of IOC Page 6 specify the configurationMPI2 specification and is specific for SSD drives only Appearing while the command is runningSas2ircu controller# delete noprompt Sas2ircu controller# display filenameDrive Type 112Initiator ID Enclosure information Enclosure# Logical IDMissing MIS The volume is missing Configuration has changed or a drive has failedFailed FLD The volume has failed Initializing Init The volume is initializingSas2ircu controller# hotspare delete EnclosureBay Sas2ircu controller# statusSas2ircu list  Volume status Enabled or Disabled Physical disk I/Os Quiesced or Not quiesced NoneSas2ircu controller# constchk volumeId noprompt Sas2ircu controller# activate volumeIdSas2ircu controller# logir action filename noprompt