Chapter 3: Creating Mirrored Volumes Creating Mirrored Volumes | SAS2 Integrated RAID Solution User Guide |
3.2.1Creating an Integrated Mirroring Volume
Disks must have
Integrated mirroring volumes must have two disks, Integrated Mirroring Enhanced volumes can have
NOTE: LSI strongly recommends that you create global hot spare disks for all mirrored volumes to increase the level of data protection. If a disk in a mirrored volume fails, the Integrated RAID firmware rebuilds it using one of the global hot spares, and the data is safe. If you create two mirrored volumes on an LSI SAS 2 controller, either of the two mirrored volumes can use the global hot spares if a disk fails.
Follow these steps to create a
1.On the Adapter List window, use the arrow keys to select an LSI SAS adapter, and then press Enter.
The Adapter Properties window appears, as the following figure shows.
Figure 5: Adapter Properties Window
2.Use the arrow keys to select RAID Properties, and then press Enter. The Create Array window appears.
3.Select Create RAID 1 Volume.
The Create New Array window appears.
Page 14 | LSI Corporation Confidential August 2010 |